Connecting
Connecting the device to IO-Link
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | [email protected] | www.turck.com
V01.00 | 2022/09 | 15
6
Connecting
6.1
Connecting the AC input voltage
The device has a 4-pin, S-coded M12 connector for connecting the AC input voltage. The max-
imum tightening torque is 0.6 Nm.
Connect the AC input voltage to the device according to the pin assignment below.
1
3
2
4
1 = L1
2 = L2
3 = L3
4 = PE
Fig. 10: Pin assignment — M12 connector, AC input voltage (XD1)
6.2
Connecting the DC output voltage side
The device has two 5-pin, L coded M12 connectors for connecting the DC output voltage side.
The maximum tightening torque is 0.6 Nm.
Connect the output voltage side according to the pin assignment shown below.
v
3
1
2
4
5
1 = 24 VDC (V1)
2 = GND (V2)
3 = GND (V1)
4 = 24 VDC (V2)
5 = PE
Fig. 11: Pin assignment — M12 connector, DC output voltage side (XD2, XD3)
Notes on connecting loads
Do not apply return voltages higher than 35 V from a load to the outputs.
Do not connect outputs or devices in parallel.
6.3
Connecting the device to IO-Link
For the connection to IO-Link, the device has a 5-pin, A-coded M12 connector. The maximum
tightening torque is 0.6 Nm.
2
3
5
4
1
1 = 24 VDC
2 = n.c.
3 = GND
4 = C/Q (IO-Link)
5 = n.c.
Fig. 12: Pin assignment - IO-Link interface (X0)