17
[email protected] • www.turck.com • 2015/02
Operation
8
Operation
WarnIng!
The devices are not safety devices.
Risk of injury caused by misuse!
➤
➤
Do not use sensors for the protection of persons or machines
nOTICE
■
Any material deposits (e.g. dust, humidity) on the surface of the sonic transducer must be prevented without
fail in order to avoid malfunction.
■
Close-range operation (blind zone S
min
) is not permitted. Refer to the technical data for the blind zone of the
sensor you are using. (sect. 15).
■
sensor
blind zone
sonic cone
object
S
min
a
coverage
teach-in-range
Fig. 8: Sonic cone and spread of the blind zone (schematic)
Operation as a diffuse mode sensor
In diffuse mode the LEDs have the following indication functions:
LED indication
Meaning
yellow
Switching output 1 on
green
NO contact: Object within the sensing range, switching output 1 off
NC contact: Object within the teach-in range, switching output 1 off
off (only NO contact)
No object within the sensing range, switching output 1 off
Operation as a retro-reflective sensor
In retro-reflective mode the LEDs have the following indication functions:
LED indication
Meaning
yellow
Reflector present, switching output 1 on
green
Object between sensor and reflector, switching output 1 off
off
No object within the sensing range, switching output 1 off
Switching output 2 inverts the signal of switching output 1.
IO-Link operation
In IO-Link mode the LEDs have the following indication function:
LED indication
Meaning
green, lit with short interruptions
IO-Link mode started
Ultr
asonic sensors
“H