Setting operation as a retro-reflective sensor
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Position the reflector in the sensing range.
➤
➤
Press and hold down the pushbutton on the adapter to U
B
for at least 21…s.
➤
➥
The sensor is set successfully as a retro-reflective sensor if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Reset to factory settings
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Starting the reset to factory settings: Press and hold down the pushbutton on the adapter to GND for 14…19 s.
➤
➤
Confirming the reset to factory settings: Press and hold down the pushbutton on the adapter for 2…7 s to
GND.
➤
➥
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of
5 Hz.
Setting output 2 as a current output
nOTE
If output 2 is set as a current output, the closer teach point corresponds to limit value 1 (4 mA) and the teach point
further away to limit value 2 (20 mA).
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Press and hold down the pushbutton on the adapter to U
B
for 2…7 s.
➤
➤
Set the limit values for the window function.
➤
➥
Output 2 is set successfully as a current output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Setting output 2 as voltage output
nOTE
If output 2 is set as a voltage output, the closer teach point corresponds to limit value 1 (0 V) and the teach point
further away to limit value 2 (10 V).
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Press and hold down the pushbutton on the adapter for 8…13 s to U
B
.
➤
➤
Set the limit values for the window function.
➤
➥
Output 2 is set successfully as a voltage output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Setting output 2 as a switching output
➤
➤
Press and hold down the pushbutton on the adapter to U
B
for 14…19 s.
➤
➥
Output 2 is set successfully as a switching output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
9.2
Setting by manual bridging (shorting)
Selecting the output
➤
➤
Select switching output 1: Bridge Pin 3 (BU) with Pin 5 (GY) for 2...7 s.
➤
➤
Select output 2: Bridge Pin 3 (BU) with Pin 5 (GY) for 8...13 s.
Setting a switch point
➤
➤
Select the switching output.
➤
➤
Position the object for the switch point.
➤
➤
Store switch point: Bridge Pin 3 (BU) with Pin 5 (GY) for 2...7 s.
➤
➥
The switch point has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.