Hans Turck GmbH & Co. KG • Tel. +49 208/4952-0 • Fax +49 208/4952-264
22
Instructions for use – Ultrasonic sensors series “High-End“
Setting output 2 as a switching output
➤
➤
Bridge Pin 1 (BU) with Pin 5 (GY) for 14...19 s.
➤
➥
Output 2 is set successfully as a switching output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
9.3
Setting via the pushbuttons
nOTE
The devices with a teach button are ready for teaching up to 300 s after the power supply is switched on. The teach
button is then automatically locked. A new teach operation is only possible after the power supply has been reset.
Selecting the output
➤
➤
Select switching output 1: Press and hold down pushbutton 1 for 2...7 s.
➤
➤
Select output 2: Press and hold down pushbutton 1 for 8...13s.
Setting a switch point
➤
➤
Select the switching output.
➤
➤
Position the object for the switch point.
➤
➤
Store switch point: Press and hold down pushbutton 1 for 2...7 s.
➤
➥
The switch point has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Window function – Setting the switching range
➤
➤
Position the object for switch point 1.
➤
➤
Select the switching output.
➤
➤
Store switch point 1: Press and hold down pushbutton 1 for 8...13s.
➤
➤
Position the object for switch point 2.
➤
➤
Store switch point 2: Press and hold down pushbutton 1 for 2...7 s.
➤
➥
The switch points have been successfully taught if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Window function– Switching between hysteresis and window
➤
➤
Position the object at any point in the sensing range.
➤
➤
Press and hold down pushbutton 1 for 8...13s.
➤
➤
Press and hold down pushbutton 1 once more for 8...13s.
➤
➥
The window has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.
➤
➥
The hysteresis has been taught successfully if the yellow LED flashes for 1.5 s at a frequency of 5 Hz.
Inverting the output function (NO/NC)
➤
➤
Select the switching output.
➤
➤
Press and hold down pushbutton 1 for 14…19 s.
➤
➥
The output function has been inverted successfully to NO if the green LED flashes for 1.5 s at a frequency of
5 Hz.
➤
➥
The output function has been inverted successfully to NC if the yellow LED flashes for 1.5 s at a frequency of
5 Hz.
Setting operation as a retro-reflective sensor
➤
➤
Position the reflector in the sensing range.
➤
➤
Press and hold down pushbutton 2 for at least 21...s.
➤
➥
The sensor is set successfully as a retro-reflective sensor if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Reset to factory settings
➤
➤
Starting the reset to factory settings: Press and hold down pushbutton 1 for 14…19 s.
➤
➤
Confirming the reset to factory settings: Press and hold down pushbutton 1 for 2...7 s.
➤
➥
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of
5 Hz.