21
[email protected] • www.turck.com • 2015/02
Setting
Window function – Setting the switching range
➤
➤
Position the object for switch point 1.
➤
➤
Select the switching output.
➤
➤
Store switch point 1: Bridge Pin 3 (BU) with Pin 5 (GY) for 8...13 s.
➤
➤
Position the object for switch point 2.
➤
➤
Store switch point 2: Bridge Pin 3 (BU) with Pin 5 (GY) for 2...7 s.
➤
➥
The switch points have been successfully taught if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Window function– Switching between hysteresis and window
➤
➤
Position the object at any point in the sensing range.
➤
➤
Bridge Pin 3 (BU) with Pin 5 (GY) for 8...13 s.
➤
➤
Bridge Pin 3 (BU) with Pin 5 (GY) for 8...13 s.
➤
➥
The window has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.
➤
➥
The hysteresis has been taught successfully if the yellow LED flashes for 1.5 s at a frequency of 5 Hz.
Inverting the output function (NO/NC)
➤
➤
Select the switching output.
➤
➤
Bridge Pin 3 (BU) with Pin 5 (GY) for 14...19 s.
➤
➥
The output function has been inverted successfully to NO if the green LED flashes for 1.5 s at a frequency of
5 Hz.
➤
➥
The output function has been inverted successfully to NC if the yellow LED flashes for 1.5 s at a frequency of
5 Hz.
Setting operation as a retro-reflective sensor
➤
➤
Position the reflector in the sensing range.
➤
➤
Bridge Pin 1 (BU) with Pin 5 (GY) for at least 21 s.
➤
➥
The sensor is set successfully as a retro-reflective sensor if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Reset to factory settings
➤
➤
Starting the reset to factory settings: Bridge Pin 3 (BU) with Pin 5 (GY) for 14...19 s.
➤
➤
Confirming the reset to factory settings: Bridge Pin 3 (BU) with Pin 5 (GY) for 2...7 s.
➤
➥
The device has been successfully reset to the factory settings if the green LED flashes for 1.5 s at a frequency of
5 Hz.
Setting output 2 as a current output
nOTE
If output 2 is set as a current output, the closer teach point corresponds to limit value 1 (4 mA) and the teach point
further away to limit value 2 (20 mA).
➤
➤
Bridge Pin 1 (BU) with Pin 5 (GY) for 2...7 s.
➤
➤
Set the limit values for the window function.
➤
➥
Output 2 is set successfully as a current output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Setting output 2 as voltage output
nOTE
If output 2 is set as a voltage output, the closer teach point corresponds to limit value 1 (0 V) and the teach point
further away to limit value 2 (10 V).
➤
➤
Bridge Pin 1 (BU) with Pin 5 (GY) for 8...13 s.
➤
➤
Set the limit values for the window function.
➤
➥
Output 2 is set successfully as a voltage output if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Ultr
asonic sensors
“H
igh End“