Hans Turck GmbH & Co.KG
•
Witzlebenstraße 7
•
45472 Mülheim/Ruhr
•
Germany
•
Tel. +49 (0)208 4952-0
•
Fax +49 (0)208 4952-264
•
•
www.turck.com
7
/1208
Parameter and Functions
Step
Parameter
Parameter value
FCMI-10D08...
Parameter value
FCMI-15D12...
Function
0
Cod
0…255
0…255
Enter access code (Factory setting 0)
1
SP
1…40
1…80
Adjustable range switch point S1 [l/min]
2
hS
0.2…5
0.2…8
Hysteresis switch point S1 [l/min]
3
OU
nO
or
nC
nO
or
nC
Output switch point S1 [NO/NC]
4
dS
0…50
0…50
Switch-on delay switch point S1 [s]
5
dr
0…50
0…50
Switch-off delay switch point S1 [s]
6
nF
I
0…8
0…8
Average forming [s]
7
A4
0…30
0…60
MIN value [l/min] for 4 mA
8
A20
10…40
20…80
MAX value [l/min] for 20 mA
9
Cod
0…255
0…255
Modifi cation of the access code
Technical data (s. also page 10)
FCMI-10D08
FCMI-15D12
Operating voltage ................................................................................... 24 VDC ± 10 % ............................................. 24 VDC ± 10 %
Current consumption ....................................................................................... < 100 mA ...................................................... < 100 mA
Switching output ................................................................ PNP, NO/NC programmable ..........................PNP, NO/NC programmable
Switching current ............................................................................................ < 200 mA ...................................................... < 200 mA
Analogue output ...................................................................................4…20 mA (linear) ...........................................4…20 mA (linear)
Analogue output with defect measuring system ...................................................... 2 mA ............................................................. 2 mA
Load R
L
............................................................................................. 200…500
Ω .......................................................
200…500
Ω
Measuring tolerance
– 1...5
l/min
.............................................................................................
≤
± 0,1 l/min ....................................................................–
– 5,1...40
l/min
........................................................................................
≤
± 2 % o. Mv. ....................................................................–
– 0...10
l/min
...............................................................................................................–
................................................
≤
± 0,2 l/min
– 10,1...80
l/min
..........................................................................................................
– ...............................................
≤
± 2 % o. Mv.
Operating range ........................................................................................... 1…40 l/min ................................................... 1…80 l/min
Adjustable range SP1 ................................................................................... 1…40 l/min ................................................... 1…80 l/min
Hysteresis SP1 ............................................................................................. 0,2...5 l/min ................................................... 0,2...8 l/min
Electrical conductivity of the medium .........................
≥
10 µS/cm (
≥
15 µS/cm for water) ................
≥
20 µS/cm (
≥
30 µS/cm for water)
Switch-on/switch-off delay ................................................................................. 0…50 s ......................................................... 0…50 s
Availability time .................................................................................................. 6…10 s ......................................................... 6…10 s
Response time .................................................................................................. 0,5…8 s ........................................................ 0,5…8 s
Sensor material ...........................................................A4 (1.4571)/AISI 316Ti and PVDF ..................A4 (1.4571)/AISI 316Ti and PVDF
Process connection material ........................................................ A4 (1.4571)/AISI 316Ti ................................. A4 (1.4571)/AISI 316Ti
Housing material .......................................................................................................PBT ...............................................................PBT
Pressure resistance ............................................................................................. 10 bar ........................................................... 10 bar
Flow rate display ...............................................................................7-segments/3 digits ...................................... 7-segments/3 digits
Connection
........................................................................................4-pole, M12 x 1 .............................................4-pole, M12 x 1
To enter the programming mode, press buttons
[S1/-]
and
[mA/+]
for at least 3 s until the display starts fl ashing.
To terminate programming and save all values press button
[M]
for at least 3 s until the display stops fl ashing.