background image

Hans Turck GmbH & Co.KG 

 Witzlebenstraße 7 

 45472 Mülheim/Ruhr 

 Germany 

 Tel. +49 (0)208 4952-0 

 Fax +49 (0)208 4952-264 

 [email protected] 

 www.turck.com

7

 

/1208

Parameter and Functions 

Step

Parameter

Parameter value

FCMI-10D08...

Parameter value

FCMI-15D12...

Function

0

Cod

0…255

0…255

Enter access code (Factory setting 0)

1

SP

1…40

1…80

Adjustable range switch point S1 [l/min]

 

2

hS

0.2…5

0.2…8

Hysteresis switch point S1 [l/min]

 

3

OU

nO 

or

 nC

nO 

or

 nC

Output switch point S1 [NO/NC]

4

dS

0…50

0…50

Switch-on delay switch point S1 [s]

5

dr

0…50

0…50

Switch-off delay switch point S1 [s]

6

nF

I

0…8

0…8

Average forming [s]

7

A4

0…30

0…60

MIN value [l/min] for 4 mA

8

A20

10…40

20…80

MAX value [l/min] for 20 mA

9

Cod

0…255

0…255

Modifi cation of the access code

Technical data (s. also page 10) 

FCMI-10D08   

FCMI-15D12

Operating voltage ................................................................................... 24 VDC ± 10 % ............................................. 24 VDC ± 10 %
Current consumption ....................................................................................... < 100 mA ...................................................... < 100 mA
Switching output  ................................................................ PNP, NO/NC programmable ..........................PNP, NO/NC programmable
Switching current  ............................................................................................ < 200 mA ...................................................... < 200 mA
Analogue output ...................................................................................4…20 mA (linear) ...........................................4…20 mA (linear)
Analogue output with defect measuring system ...................................................... 2 mA ............................................................. 2 mA
Load R

   

 ............................................................................................. 200…500 

Ω .......................................................

200…500 

Ω

Measuring tolerance
– 1...5 

l/min  

.............................................................................................

 ± 0,1 l/min ....................................................................–

– 5,1...40 

l/min 

........................................................................................

≤ 

± 2 % o. Mv. ....................................................................–

– 0...10 

l/min 

 

...............................................................................................................–

 

 ................................................

 ± 0,2 l/min

– 10,1...80 

l/min 

..........................................................................................................

 

– ...............................................

≤ 

± 2 % o. Mv.

Operating range ........................................................................................... 1…40 l/min ................................................... 1…80 l/min 
Adjustable range SP1 ................................................................................... 1…40 l/min ................................................... 1…80 l/min
Hysteresis SP1 ............................................................................................. 0,2...5 l/min ................................................... 0,2...8 l/min
Electrical conductivity of the medium .........................

 10 µS/cm (

 15 µS/cm for water) ................

 20 µS/cm (

 30 µS/cm for water)

Switch-on/switch-off delay ................................................................................. 0…50 s ......................................................... 0…50 s 
Availability time  .................................................................................................. 6…10 s ......................................................... 6…10 s
Response time .................................................................................................. 0,5…8 s ........................................................ 0,5…8 s
Sensor material ...........................................................A4 (1.4571)/AISI 316Ti and PVDF ..................A4 (1.4571)/AISI 316Ti and PVDF
Process connection material ........................................................ A4 (1.4571)/AISI 316Ti  ................................. A4 (1.4571)/AISI 316Ti
Housing material .......................................................................................................PBT ...............................................................PBT 
Pressure resistance  ............................................................................................. 10 bar ........................................................... 10 bar
Flow rate display ...............................................................................7-segments/3 digits ...................................... 7-segments/3 digits
Connection 

 ........................................................................................4-pole, M12 x 1 .............................................4-pole, M12 x 1

To enter the programming mode, press buttons 

[S1/-]

 and 

[mA/+]

 for at least 3 s until the display starts fl ashing.

To terminate programming and save all values press button 

[M]

 for at least 3 s until the display stops fl ashing.

Содержание FTCI-G1/4A4-D10/L050

Страница 1: ...e 7 45472 M lheim Ruhr Germany Tel 49 0 208 4952 0 Fax 49 0 208 4952 264 more turck com www turck com 1 1208 DURCHFLUSS MESSER FCMI FLOW METER FCMI CONTR LEUR DE D BIT FCMI BEDIENUNGS ANLEITUNG INSTR...

Страница 2: ...e Magnetic inductive flow meter housing style inline Contr leur de d bit magn tique inductif format Inline Typenschl ssel Type Code Codification H1141 Mechanischer Anschluss mechanical connection conn...

Страница 3: ...min Mounting the compression ferrule fitting If no pipe adapters are used then a precision grade pipe meeting the require ments of EN 10305 1 must be used The pipes must feature the diameter and wall...

Страница 4: ...Messwertes In der Einstellung 0 ist die Mittelwertbildung ausgeschaltet Die Mittelwertbildung wirkt auf Anzeige und Stromausgang Analogausgang A4 und A20 Diese beiden Werte legen den Durchfluss bereic...

Страница 5: ...0 5 8 s Material Sensor A4 1 4571 AISI 316Ti und PVDF A4 1 4571 AISI 316Ti und PVDF Material Prozessanschluss A4 1 4571 AISI 316Ti A4 1 4571 AISI 316Ti Material Geh use PBT PBT Druckfestigkeit 10 bar...

Страница 6: ...value can be modified at the end of the programming menu Adjustable range switch point S1 SP The switch point S1 is entered in l min The switch point may be placed anywhere within the total adjustable...

Страница 7: ...rammable Switching current 200 mA 200 mA Analogue output 4 20 mA linear 4 20 mA linear Analogue output with defect measuring system 2 mA 2 mA Load RL 200 500 200 500 Measuring tolerance 1 5 l min 0 1...

Страница 8: ...in du menu de programmation Plage de r glage du point de com mutation S1 SP Le point de commutation S1 est introduit dans l unit l min Le point de commutation peut se trouver dans l ensemble de la pla...

Страница 9: ...O NC Courant de commutation 200 mA 200 mA Sortie analogique 4 20 mA lin aire 4 20 mA lin aire Sortie analogique pour un syst me de mesure d fectueux 2 mA 2 mA Charge RL 200 500 200 500 D rive 1 5 l mi...

Страница 10: ...res 4 5 4x 3 100 63 24 53 63 Adapter Adapter Adaptateur Montageplatte Mounting panel Plaque de montage Arbeitsbereich Operating range Plage de fonction l min Ausgangs funktion Output function Fonction...

Страница 11: ...um Anschluss 4 Connection 6 Connexion 8 Medien temperatur Medium temperature Temp rature milieu C Umgebungs temperatur Ambient temperature Temp rature ambiante C Schutzart Degree of protection Mode de...

Страница 12: ...ans Turck GmbH Co KG Witzlebenstra e 7 45472 M lheim an der Ruhr Germany Tel 49 0 208 4952 0 Fax 49 0 208 4952 264 E Mail more turck com Internet www turck com www turck com D101656 1208 Hans Turck Gm...

Отзывы: