Wire and wire tensioners are fitted in the four brackets 
on the side of the unit. Tension is applied to the wires 
between the supplied bracket mounted on purlins and 
battens. The purpose of the wires is to adjust and 
keep the unit in a vertical position. 
 
 
 
 
 
The inlet ring is pushed onto the unit and secured 
using self-tapping screws from both inside and 
outside. Now proceed to complete the roofing. 
 
 
 
 
 
 
The soft cover is pulled over the unit. Seal the edge 
using silicone rubber. Use silicone rubber under the 
vertical part of the cover and on the top of the edge to 
secure a watertight joint. 
 
When the cover is cut, please note you will need a  
10 cm overlap with the overlying roof tile or ridge. 
The hole in the cover is cut using the same template 
used for cutting the hole in the roof. 

The hole in the cover must be cut in a diameter 
about 5 cm smaller than that of the template to 
ensure a tight fit. 

The soft cover is fastened using self-tapping screws 
and needs to be no more than 15 mm inside the unit 
to ensure ample space for the rotating parts in the 
unit. 

 

 
 
 
The filter holders are sealed with silicone rubber and 
secured using self-tapping screws. 
 
The top cone is screwed in place using M8 bolts. 

Silicone grout 

Min 10 cm overlap 

Silicone 

Содержание TX 3100A

Страница 1: ...Page 1 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk User manual Installation guide TX 3100A Rev 2018 04 12...

Страница 2: ...IST OF PARTS 3 3 4 0 FUNCTION OF THE UNIT 4 4 0 0 INSTALLATION 5 4 1 0 DIMENSIONS 5 4 2 0 PLACEMENT 6 4 3 TEMPLATE 6 4 4 0 INSTALLING THE UNIT STANDARD MOUNTING BRACKETS 7 4 5 0 INSTALLING THE UNIT US...

Страница 3: ...ventilation unit Turbovex TX 3100A 3 2 0 Field of application Turbovex TX 3100A is designed for comfort ventilation in industrial buildings garages and sports halls 3 3 0 List of parts Turbovex TX 310...

Страница 4: ...ltaneously the inlet fan will C sucks air from the inlet cap G and send it through the other half of the heat exchanger The heated fresh air is sent to E and diffused in the room One half of the rotat...

Страница 5: ...Page 5 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 4 0 0 Installation 4 1 0 Dimensions Adjust for brackets...

Страница 6: ...andard mounting bracket places the inspection hatch inside the building The special mounting bracket is intended for use if you want the hatch placed outside the building 4 3 Template It is a good ide...

Страница 7: ...e purlins at a distance of 1000 mm between the two brackets The mounting brackets are secured using mounting screws top and bottom The forks on the bracket are adjusted so they are directly opposite a...

Страница 8: ...using silicone rubber Use silicone rubber under the vertical part of the cover and on the top of the edge to secure a watertight joint When the cover is cut please note you will need a 10 cm overlap w...

Страница 9: ...mplate see 4 3 0 template and cut a hole in the wooden frame and the rest of the roof One part of the soft cover is mounted on the frame and the hole is cut out The other cover is fastened so it cover...

Страница 10: ...tch is faced away from the ridge of the roof for better access The large electric control unit can be moved to a different location if needed The filter holders are sealed using silicone rubber seal a...

Страница 11: ...e unit won t be leaky First mount the inner tube and then the outer tube on the unit The intake ring is mounted on the extension tubes The filter and the angle brackets are reattached The brackets are...

Страница 12: ...e marked with yellow marks Make sure the drain hole is located above the blinded hole on the unit The electrical cubicle is screwed onto the spiral duct and wiring installed in accordance with the wir...

Страница 13: ...x750 Watt Energy consumption 3000 m3 h 1044 W 1 25 KJ m3 Heat recovery 3000 m3 h 75 Turbovex TX 3100A is tested in cooperation with Ziehl abegg www ziehl abegg com The airflow indicates the balanced a...

Страница 14: ...Page 14 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 6 0 0 Electrical installation...

Страница 15: ...Page 15 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk...

Страница 16: ...Page 16 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk...

Страница 17: ...Page 17 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk...

Страница 18: ...of inlet filter Replacement of exhaust filter Cleaning of heat exchanger Overall inside cleaning of unit Damper exhaust motor Hinges on the damper flap Fan motor inlet Fan motor exhaust Rot heat exch...

Страница 19: ...filter is placed in the bottom of the unit and is easy to remove and replace a new one The only ting there is holding the filter is a rubber on the edge of the filter The rubber seal must be placed s...

Страница 20: ...Page 20 of 20 Turbovex A S Industrivej 45 DK 9600 Aars Telefon 45 96 98 14 62 Fax 45 98 96 42 24 e mail info turbovex dk www turbovex dk 8 0 0 Declaration of conformity...

Отзывы: