U s e r I n s t r u c t i o n s
Eco-Net 128 Control Unit
InMn 26 UCESTD
it Rev.1.02
TURBO s.r.l.
Dust Filter Components
Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092
17
Operating mode
The operating modes of the Eco-Net 128 control unit are shown below. They can be activated by setting
the relative parameter of the "Main Set Up" menu.
Manual mode
In this mode, the Eco-Net 128 control unit operates as a programmable cyclic sequencer. The Bus valves
will be activated sequentially, at programmed intervals of time.
The activation times of the valves can be
programmed using the same menu; modifying the
"Pulse time" (Ts), "Cycle time" (Tc) and setting the
overall number of valves (Vx) that make up the
system.
Automatic mode
In this mode, the Eco-Net 128 control unit operates autonomously, performing the cleaning cycle only
when necessary. The cycle starts when the pressure threshold set in the "dP Start Cleaning" parameter is
exceeded.
The valves are activated in sequential mode, following the times indicated in manual mode.
If the pressure differential drops below the "dP Stop
Cleaning" value set, the cleaning cycle will be
suspended and will start again when the "dP Start
Cleaning" value is exceeded.