Dust Filter Components
Via Po 33/35 20811 Cesano Maderno (MB) Italy Tel ++39 0362 574024 Fax ++39 0362 574092
InMn 26 UCESTD
Rev.1.02 it
Alarms
Description
Unit
of
measurement
Factory
settings
Range
3.1
dP Dirty filter
Set the pressure ΔP value to generate
the clogged filter alarm
KPa/1000
3000
0
10000
3.2
Enabling Min. dP
The broken hose alarm function is
enabled
Disable
Enable
Disable
3.3
Low Alarm Thres dP
Set the pressure ΔP value to generate
the minimum pressure alarm
KPa/1000
200
0
10000
3.4
Hourmeter Fan
The extraction functioning hour count
function is set through the input on
connector P17
Disable
Enable
Disable
3.5
Replace Filters (h)
The number of hours desired to signal the
filtering elements replacement
intervention is set. Signalling is subject
to the activation of the Hourmeter Fan
function.
Hours
1000
0
10000
Calibration / Test
Description
Unit
of
measurement
Factory
settings
Range
4.1
No. valves (+/- =ON)
The Bus valves are activated manually for
system test
1
1
127
4.2
Zero dP
The Zero ΔP pressure calibration is
performed, simultaneously pressing the
“+” and “
-
“ buttons.
KPa
0
0
100
4.3
4 mA Output
The 4mA output value, which corresponds
to Zero ΔP pressure, is set
650
0
3600
4.4
20 mA Output
The 20mA output value, which
corresponds to full scale ΔP pressure, is
set
3290
0
3600