Turbo E8T Скачать руководство пользователя страница 23

U s e   A n d   M a i n t e n a n c e   I n s t r u c t i o n s

 

E c o n o m i z e r   E 8 T   1 6   O u t p u t   C h a n n e l s

 

 

I n M n     E E 8 T  
e n     R e v . 0 0  

T U R B O   S r l

    D u s t   F i l t e r   C o m p o n e n t s  

V i a   P o   3 3 / 3 5   2 0 8 1 1   C e s a n o   M a d e r n o   ( M B )   I t a l y     T e l   + + 3 9   0 3 6 2   5 7 4 0 2 4     F a x   + + 3 9   0 3 6 2   5 7 4 0 9 2  

2 3  

 

Default Settings 

The default settings are: 

 

S e t t i n g  

V a l u e  

Operating Mode 

Automatic 

Start Of Cleaning Dp  

0.80 kPa 

End Of Cleaning Dp 

0.40 kPa 

Pulse Time Valves 

200 m.sec. 

Pause Time Cycle Valves 

20 sec. 

Post-Cleaning Activation 

0.10 kpa  

Number Of Valves 

Cleaning When Fan Is Off 

Pulse Time V. Cleaning Fan Off 

200 m.sec. 

Pause Time V. Cleaning Fan Off 

20 sec. 

Start Precoating dP 

1.50 kpa 

Language 

Italian 

Maintenance 

The control unit has no parts that can be replaced, except for the fuse. 

All repair operations must be carried out by the manufacturer. 

To clean dust and dirt from the surfaces, gently rub with cotton or other 

soft cloth soaked with non-aggressive, non-abrasive detergents, use 
those used for glass surfaces; do not use solvents or aromatic compounds and 
do not rub with abrasive sponges. 

 

Scrapping 

Dispose of properly after use. Dispose of the product according to laws 
in force for electronic equipment. 

This device is for use in a dust collection system and is therefore part of 
a fixed installation. Warranty 

 

 

 

 

 

 

 

 

 

 

 

Содержание E8T

Страница 1: ...hannels I n Mn EE8 T en Rev 00 TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 1 Ec...

Страница 2: ...be ____________________________________________________________17 Operation Description_________________________________________________________ 18 Manual Operating Mode ______________________________...

Страница 3: ...or the control of industrial dust collector system pneumatic cleaning Differential pressure digital control through internal transducer which allows the accurate analysis of the cleaning filter cloggi...

Страница 4: ...Proportionate To Dp Value For Remote Pressure Reading from 4 to 20mA x 1 Power Consumption 28 Watts Maximum Load Alarm Relays 3 Normally Closed Display Graphic LCD Backlit Monochromatic B W 128 x 64...

Страница 5: ...ectable values for any application Cleaning function with fan off post cleaning by dP fan threshold in automatic proportional mode and by contact in manual special manual modes with selectable number...

Страница 6: ...Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn E E8T Rev 0 0 en Dimensions And M...

Страница 7: ...s which could generate network interference or instability The unit electric power supply must be protected by a 230Vac 30mA Residual Current Device RCD and a bipolar 230Vac 10A magnet circuit breaker...

Страница 8: ...nut Any use not described in this user instruction manual or incorrect use of the device may cause damage to the device or to the equipment connected to it Furthermore incorrect use or tampering with...

Страница 9: ...TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 9 Electrical Connections To connec...

Страница 10: ...o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn E E8T Rev 0 0 en Jumper Configuration Power Input 115 VAC 230 VAC In the 24Vac and 24Vdc versions J3 and J4...

Страница 11: ...ovides access to settings it is used as RESET in the event of alarms Keys Increase and decrease the values manually start valves in Test mode used to scroll any alarms The S key starts stops solenoid...

Страница 12: ...OK key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters Operative M...

Страница 13: ...hile cleaning cycles are started with the fan off under it Post Cleaning Cleaning Fan off Number of complete cleans with fan off for the number of connected solenoid valves Pulse Time Valve opening ti...

Страница 14: ...s exit to save and exit Set Operation Selectable Parameters dP Dirty Filter Enter the dP threshold to trigger the clogged filter alarm Enabling Minimum dP Minimum dP alarm enabling broken sleeve Low A...

Страница 15: ...K key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters No Valve ON...

Страница 16: ...ters Press OK key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters...

Страница 17: ...ltiple of 0 5 Sec 300 Threshold Alarm 0 01 mg m 1500 Time Alarm Recognition Multiple of 0 5 Sec 60 Threshold Peak 0 01 mg m 3000 Time Recognition Peak Multiple of 0 5 Sec 10 Reference Emissions 0 01 m...

Страница 18: ...ic cleaning only when necessary If the device detects clogging over the dP Start Cleaning threshold cleaning is started If clogging drops under the dP Stop Cleaning threshold cleaning is suspended and...

Страница 19: ...s pressure constant and it is hard to work with automatic and proportional modes Other Function Descriptions Alarms This function allows an alarm device to be connected The alarm device can be connect...

Страница 20: ...uration between one solenoid valve start and the next during post cleaning Pulse time cleaning pulse duration regardless of the fan on operating time Selecting The Number Of Outputs The number of outp...

Страница 21: ...5 7 4 0 9 2 21 4 20mA Out Function This function lets you check pressure readings from remote through 4 20mA transmitter Connect the signal to be sent to the remote device to terminals 10_11 on connec...

Страница 22: ...ipes between device and filter are not obstructed or damaged The cleaning cycle is not carried out The economizer is in economy mode and therefore does not start up Adjust the start up pressure thresh...

Страница 23: ...hen Fan Is Off 2 Pulse Time V Cleaning Fan Off 200 m sec Pause Time V Cleaning Fan Off 20 sec Start Precoating dP 1 50 kpa Language Italian Maintenance The control unit has no parts that can be replac...

Страница 24: ...ill replace any electronic component deemed defective exclusively at our workshop except in the presence of contrary agreements to be authorized by the company Warranty Exclusions The warranty will be...

Страница 25: ...The manufacturer s address V i a P o 3 3 3 5 2 0 8 1 1 C e s a n o M a d e r n o I t a l y Declares that the product E c o n o m i z e r Model E 8 T Complies with the following directives Directive 2...

Отзывы: