Turbo E8T Скачать руководство пользователя страница 2

 

U s e   A n d   M a i n t e n a n c e   I n s t r u c t i o n s

E c o n o m i z e r   E 8 T   1 6   O u t p u t   C h a n n e l s

 

2  

T U R B O   S r l

    D u s t   F i l t e r   C o m p o n e n t s  

V i a   P o   3 3 / 3 5   2 0 8 1 1   C e s a n o   M a d e r n o   ( M B )   I t a l y     T e l   + + 3 9   0 3 6 2   5 7 4 0 2 4     F a x   + + 3 9   0 3 6 2   5 7 4 0 9 2  

I n M n   E E 8 T

R e v . 0 0     e n  

 

Description  ____________________________________________________________________  3

 

Technical Specifications ________________________________________________________  4

 

Dimensions And Measurements  ________________________________________________  6

 

Warning Symbols Used In This Manual _________________________________________  7

 

Installation Regulations and Warnings__________________________________________  7

 

Electrical Connections __________________________________________________________  9

 

Jumper Configuration Power Input ____________________________________________  10

 

Jumper Configuration Output Voltage _________________________________________  10

 

Keyboard And Monitor _________________________________________________________ 11

 

Menu Layout __________________________________________________________________  12

 

Basic Settings _______________________________________________________________________  12

 

Advanced Settings  __________________________________________________________________  13

 

Alarms  ______________________________________________________________________________  14

 

Calibration /  Test  ___________________________________________________________________  15

 

Counters ____________________________________________________________________________  16

 

Tribo Electric Probe ____________________________________________________________17

 

Operation Description_________________________________________________________  18

 

Manual Operating M ode  ____________________________________________________________  18

 

Automatic Operating Mode  _________________________________________________________  18

 

Proportional Operati ng Mode _______________________________________________________  18

 

Special Manual Operating Mode  ____________________________________________________  19

 

Other Function Descriptions___________________________________________________  19

 

Alarms  ______________________________________________________________________________  19

 

Cleaning Function With Fan Off Post-Cleaning ______________________________________ 20

 

Selecting The Numb er Of Outpu ts  __________________________________________________ 20

 

Pre-Coating Function  _______________________________________________________________ 20

 

Cleaning Function From Remote Control  ____________________________________________ 20

 

4-20mA Out Function _______________________________________________________________  21

 

4-20mA IN Function _________________________________________________________________  21

 

Trouble Shooting 

FAQ

  ________________________________________________________ 22

 

Default Settings _______________________________________________________________ 23

 

Maintenance __________________________________________________________________ 23

 

Scrapping _____________________________________________________________________ 23

 

Warranty ______________________________________________________________________ 24

 

Warranty Exclusions ___________________________________________________________ 24

 

Declaration Of Conformity Of The Manufacturer  ______________________________ 25

 

 

Содержание E8T

Страница 1: ...hannels I n Mn EE8 T en Rev 00 TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 1 Ec...

Страница 2: ...be ____________________________________________________________17 Operation Description_________________________________________________________ 18 Manual Operating Mode ______________________________...

Страница 3: ...or the control of industrial dust collector system pneumatic cleaning Differential pressure digital control through internal transducer which allows the accurate analysis of the cleaning filter cloggi...

Страница 4: ...Proportionate To Dp Value For Remote Pressure Reading from 4 to 20mA x 1 Power Consumption 28 Watts Maximum Load Alarm Relays 3 Normally Closed Display Graphic LCD Backlit Monochromatic B W 128 x 64...

Страница 5: ...ectable values for any application Cleaning function with fan off post cleaning by dP fan threshold in automatic proportional mode and by contact in manual special manual modes with selectable number...

Страница 6: ...Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn E E8T Rev 0 0 en Dimensions And M...

Страница 7: ...s which could generate network interference or instability The unit electric power supply must be protected by a 230Vac 30mA Residual Current Device RCD and a bipolar 230Vac 10A magnet circuit breaker...

Страница 8: ...nut Any use not described in this user instruction manual or incorrect use of the device may cause damage to the device or to the equipment connected to it Furthermore incorrect use or tampering with...

Страница 9: ...TURBO Srl Du s t F i l t e r C om p on en t s Vi a P o 3 3 3 5 2 0 8 1 1 Ce san o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 9 Electrical Connections To connec...

Страница 10: ...o M a de rn o M B I t al y Te l 3 9 0 3 6 2 5 7 4 0 2 4 Fa x 3 9 0 3 6 2 5 7 4 0 9 2 I n Mn E E8T Rev 0 0 en Jumper Configuration Power Input 115 VAC 230 VAC In the 24Vac and 24Vdc versions J3 and J4...

Страница 11: ...ovides access to settings it is used as RESET in the event of alarms Keys Increase and decrease the values manually start valves in Test mode used to scroll any alarms The S key starts stops solenoid...

Страница 12: ...OK key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters Operative M...

Страница 13: ...hile cleaning cycles are started with the fan off under it Post Cleaning Cleaning Fan off Number of complete cleans with fan off for the number of connected solenoid valves Pulse Time Valve opening ti...

Страница 14: ...s exit to save and exit Set Operation Selectable Parameters dP Dirty Filter Enter the dP threshold to trigger the clogged filter alarm Enabling Minimum dP Minimum dP alarm enabling broken sleeve Low A...

Страница 15: ...K key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters No Valve ON...

Страница 16: ...ters Press OK key Use the arrows to select the item to be set Use keys to increase or decrease the value and change the item conditions Press exit to save and exit Set Operation Selectable Parameters...

Страница 17: ...ltiple of 0 5 Sec 300 Threshold Alarm 0 01 mg m 1500 Time Alarm Recognition Multiple of 0 5 Sec 60 Threshold Peak 0 01 mg m 3000 Time Recognition Peak Multiple of 0 5 Sec 10 Reference Emissions 0 01 m...

Страница 18: ...ic cleaning only when necessary If the device detects clogging over the dP Start Cleaning threshold cleaning is started If clogging drops under the dP Stop Cleaning threshold cleaning is suspended and...

Страница 19: ...s pressure constant and it is hard to work with automatic and proportional modes Other Function Descriptions Alarms This function allows an alarm device to be connected The alarm device can be connect...

Страница 20: ...uration between one solenoid valve start and the next during post cleaning Pulse time cleaning pulse duration regardless of the fan on operating time Selecting The Number Of Outputs The number of outp...

Страница 21: ...5 7 4 0 9 2 21 4 20mA Out Function This function lets you check pressure readings from remote through 4 20mA transmitter Connect the signal to be sent to the remote device to terminals 10_11 on connec...

Страница 22: ...ipes between device and filter are not obstructed or damaged The cleaning cycle is not carried out The economizer is in economy mode and therefore does not start up Adjust the start up pressure thresh...

Страница 23: ...hen Fan Is Off 2 Pulse Time V Cleaning Fan Off 200 m sec Pause Time V Cleaning Fan Off 20 sec Start Precoating dP 1 50 kpa Language Italian Maintenance The control unit has no parts that can be replac...

Страница 24: ...ill replace any electronic component deemed defective exclusively at our workshop except in the presence of contrary agreements to be authorized by the company Warranty Exclusions The warranty will be...

Страница 25: ...The manufacturer s address V i a P o 3 3 3 5 2 0 8 1 1 C e s a n o M a d e r n o I t a l y Declares that the product E c o n o m i z e r Model E 8 T Complies with the following directives Directive 2...