![Tucker KP evo Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/tucker/kp-evo/kp-evo_installation-manual_1179291026.webp)
920.1044 | 24
6.1 INTERMODE
15
shows the ID to assign to the 950N2 units in the
network.
The system consists of a Master unit and a maximum
of 14 Slave units. The 950N2 Master unit is the only
one on which the operating mode should be set, which
is then also applied immediately to all the Slave units.
------------------------------------------------------------------------------------------------------------------------------------
With INTERMODE, it is not possible to change the
operating mode of an individual unit.
-----------------------------------------------------------------------------------------------------------------------------------
950N2 The Master must be assigned ID1 and the Slave
units with ID from 2 to 14.
6.2 INTERLOCK
16
shows the ID to assign to the 950N2 units in
the network. Either of the two units can be designated as
the Master and the other as the Slave. In INTERLOCK
mode, one door can open only if the other is closed. The
available variations are shown below.
If the PARTIAL mode is associated with INTERLOCK,
only the Master leaf opens.
------------------------------------------------------------------------------------------------------------------------------------
Connect the devices and carry out the
programming and Setup of the individual 950N2
units before configuring the INTERLOCK using
KP EVO.
Select on the Master unit to activate the
INTERLOCK
-----------------------------------------------------------------------------------------------------------------------------------