![Tucker KP evo Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/tucker/kp-evo/kp-evo_installation-manual_1179291013.webp)
920.1044 | 11
EMERGENCY OPEN
When activated, the door opens (always total) and
remains open as long as the input is active. When
released, the door waits for the night pause time to
elapse and then closes. Also active in NIGHT mode.
EMERGENCY OPEN WITH MEMORY
When activated, the door opens (always total) and
remains open as long as the input is active. When
released, the door remains open until it is Reset
EMERGENCY CLOSE
When activated, the door closes and remains closed as
long as the input is active. When released, the door
returns to normal operation.
EMERGENCY CLOSE WITH MEMORY
When activated, the door closes and remains closed as
long as the input is active. When released, the door
remains closed until it is Reset
FIRE ALARM
When activated, the door closes, regardless of the
operating mode that has been set, with the lock kept in
the released position. It has priority over any commands
that may be active.
ALWAYS OPEN
When activated, the ALWAYS OPEN mode is set.
EXIT ONLY
When activated, the EXIT ONLY mode is set.
ENTRY ONLY
When activated, the ONLY IN operating mode is set.
NIGHT
When activated, the NIGHT mode is set.
MANUAL
When activated, the MANUAL mode is set.
PARTIAL
When activated, the PARTIAL mode is set.
INTERLOCK ON
When activated, the INTERLOCK mode is set.
TIMER
When activated, the TIMER mode is set.
OUTPUTS
The outputs on terminal board J5 of the I/O board can be
configured with the following functions
------------------------------------------------------------------------------------------------------------------------------------------
Each input can be set to NC or NO according to
the device connected to it.
------------------------------------------------------------------------------------------------------------------------------------------
DISABLED
No associated function.
GONG
The output is activated and deactivated at 1-second
intervals when the safety devices are engaged.
ERROR
The output is activated if there is an error.
EMRG. ACTIVE
The output is activated when an Emergency is
triggered.
TEST
The output commands a FAILSAFE test on the inputs
that are conjured as safety devices on which the option
of running a TEST before movement has been enabled.
DOOR NOT CLOSED
The output remains active until the door is closed.
DOOR OPEN
The output remains active as long as the door is open.
DOOR OPENING
The output remains active as long as the door is
moving.
LIGHT
The output is activated, for a programmable length of
time, when the door is open in NIGHT mode.
INTRUSION ACTIVE
The output is activated when an intrusion is in progress
(i.e. when an unexpected movement of the door from
its closed position is detected).
CLOSING SAFETY
The output is activated when a closing safety device is
active.
SAFETIES
The output is activated when a closing or opening
safety device is engaged.
OP/CL RELAY
Species the logic of the door status relay (NC/NO).
EXTERNAL SELECTOR
Species the operating mode associated with positions 1
and 2 of the selector on the side of the unit.
■
PROGRAMMING – TIMING
PAUSE TIME
Denes the pause time of the door when opened by a
command, before closing automatically.
PAUSE TIME P&G
Sets the door pause time when opened by a Push & Go
command, before closing automatically.
NIGHT PAUSE TIME
Sets the door pause time when opened by a command
in NIGHT mode, before closing automatically.