![Tucker KP evo Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/tucker/kp-evo/kp-evo_installation-manual_1179291012.webp)
920.1044 | 10
■
PROGRAMMING INPUTS/OUTPUTS INPUTS
The inputs on terminal board J5 of the I/O board can be
conjured with the following functions
-----------------------------------------------------------------------------------------------------------------------------------------
Each input can be set to NC or NO according to
the device connected to it.
------------------------------------------------------------------------------------------------------------------------------------------
DISABLED
No associated function.
EXTERNAL OPEN
When activated, the door opens and remains open as long
as the input is active. When released, the door waits for
the pause time to elapse and then closes. This has no
effect in the EXIT ONLY or NIGHT modes.
INTERNAL OPEN
When activated, the door opens and remains open as long
as the input is active. When released, the door waits for
the pause time to elapse and then closes. This has no
effect in the ONLY IN or NIGHT modes.
AUTOMATIC OPEN
When activated, the door opens and remains open as long
as the input is active. When released, the door waits for
the pause time to elapse and then closes. Active in the BI-
DIRECTIONAL, EXIT ONLY and ONLY IN modes. This has no
effect in the NIGHT mode.
SEMIAUTOM.OPEN
When activated:
- if the door is not already open, it opens and remains
open
- if the door is already open, it closes
Active in the BI-DIRECTIONAL, EXIT ONLY and ONLY IN
modes. This has no effect in the NIGHT mode.
KEY
When activated, the door opens and remains open as
long as the input is active. When released, the door
waits for the night pause time to elapse and then
closes. Active in the BI-DIRECTIONAL, EXIT ONLY, IN
ONLY and NIGHT modes.
PARTIAL OPEN
Only opens the master door when activated in the “2
leaves” mode.
CLOSING SAFETY
When activated:
- If the door is closing, it reopens
- If the door is already open, it prevents it from closing
- If the door is opening, it has no effect
OPENING SAFETY
When activated:
- If the door is opening, it stops until it is released
- If the door is already closed, it prevents it from
opening
- If the door is closing, it has no effect