![Tucker KP evo Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/tucker/kp-evo/kp-evo_installation-manual_1179291018.webp)
920.1044 | 16
F STATUS
2.5 ERRORS
Errors are malfunctions that prevent the automation
system from working. They are indicated by a steady
red LED on the Logic board. After every 5 minutes in
which a fault condition persists and for a maximum of
20 consecutive times, the 950N2 will perform a Reset
to attempt to restore normal operation so as not to
require any action if the condition that caused the
error was temporary. If the fault persists, remove the
cause in order to restore normal operation. The type
of error can be identified via the KP EVO The error
code appears on the home page. Go to menu 5; the
display provides information regarding the current
error.