![Tucker KP evo Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/tucker/kp-evo/kp-evo_installation-manual_1179291022.webp)
920.1044 | 20
4. PUTTING INTO SERVICE
4.1 FINAL CHECKS
1. For doors in “low energy” mode, make sure that the forces generated by the leaf are within the limits permitted
by the regulations. Use an impact force tester in accordance with standards EN 12453: 2002 and EN 12445:
2002. For non-EU countries, of there are no specific local regulations, the force must be less than 67 N.
2. For doors that are not in “low energy” mode, make sure that the test object is detected in all areas covered by
the leaf movement.
4.2 FINAL OPERATIONS
1. Connect the cable of the functions selector at the side of the unit to the I/O board (connector J2).
2. Install the front cover.
3. Highlight all areas with adequate warning signs in which there are still residual risks, even if all possible safety
measures having been adopted. In particular, for doors less than 2 meters high, apply the hazard warning
pictograms in correspondence with the arm movement area.
4. Place a “DANGER, AUTOMATICALLY CONTROLLED” sign in a prominent position on the door.
5. Attach the CE marking on the door.
6. Fill out the EC declaration of conformity and the system register.
7. Give the EC Declaration, the system register with the maintenance plan and the instructions for use of the
automation to the system owner/operator.
Содержание KP evo
Страница 1: ...920 1044 KP evo TAP CONTROLLER ...
Страница 2: ......
Страница 9: ...920 1044 07 ...
Страница 10: ...920 1044 08 ...
Страница 11: ...920 1044 09 ...
Страница 19: ...920 1044 17 G ERRORS ...