TTI Elite 100 Скачать руководство пользователя страница 6

 

 

MINIMAL MAINTENANCE 

Your new heat pump has been designed to necessitate minimal maintenance. However, if you want your 
pool to be heated as efficiently as possible, you should abide by the installation and maintenance advice 
contained in this document. 
 

POSITIONING 

Choosing the area where your heat pump will be installed is extremely important. You must respect the 
following guidelines. 
 

VENTILATION AND ACCESSIBILITY 

Your heat pump works, in large part, in symbiosis with the surrounding air: it is important that there be 
adequate ventilation all around the heat pump. Therefore, the device should not be installed in a closed 
space such as a garden shed or a basement. 

 
IMPORTANT:

 Your heat pump must have sufficient free space around it to function properly. 

 
You should also clear any obstructions surrounding the heat pump, as indicated in the table below: 
 

 

ALL MODELS 

(1) in front of the evaporation coil 

60 cm = 2 feet 

(2) in front of all other surfaces 

35 cm = 14 inches 

(3) in front of the fan* 

120 cm = 4 feet 

(4) in front of the service panel 

60 cm = 2 feet 

*Objects should be placed as far away as possible from the area where air is evacuated.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OTHER RECOMMENDATIONS 

You should not install the device below a roof, so that your heat pump becomes buried under snow or 
receives too much water if the roof is not fitted with gutters. Do not install your heat so that the sun 
directly hits the regulator. This will not cause damages, but the display will be harder to read. 
Similarly, you should not install automatic sprinkler near your pool heat pump. The device must be 
installed on a flat, firm and level surface. A concrete slab or equivalent is preferred. Consider that your 
device will produce condensation, so there will be water leaking around the unit. 
 
 

1

 

 

1

 

 

Содержание Elite 100

Страница 1: ...E 55 65 85 100 115 130 IMPORTANT It is important to register your product with us on our web site This will help us find your warranty when you place a service call If we cannot find your warranty reg...

Страница 2: ...r removing any Elite equipment make sure that all breakers covering the pool area have been turned off A clearly identified breaker must be installed in order to be able to interrupt power to the heat...

Страница 3: ...re outlined on the rating plate Elite heat pumps have a 240V 1 phase voltage Make sure you have the appropriate electrical connections Make sure that there is no watering or sprinkler system near or a...

Страница 4: ...inimum and maximum water flows IV CHLORINATORS BROMINATORS AND OTHERS P 8 9 Basic connections inline chlorinator or brominator Salt chlorinator Pressurized chlorinator or brominator Parallel connectio...

Страница 5: ...Your heat pump does not produce heat just like a water pump does not produce water with the energy it consumes Thus it is possible to achieve yields of up to 600 or 700 under optimum conditions or a...

Страница 6: ...clear any obstructions surrounding the heat pump as indicated in the table below ALL MODELS 1 in front of the evaporation coil 60 cm 2 feet 2 in front of all other surfaces 35 cm 14 inches 3 in front...

Страница 7: ...denser An adjustable automatic bypass valve must be installed when a water pump of 2 HP or more is used to circulate the pool water Your water pump must be able to supply each heat pump with a water f...

Страница 8: ...ot compliant to this rule SALT CHLORINATORS Salt chlorinators are made to be installed as inline chlorinators Therefore they must be installed as prescribed in the section above inline chlorinator or...

Страница 9: ...reaker must be installed close to the heat pump in an accessible location Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump If your he...

Страница 10: ...nse the condenser with tap water and drain the system with air pressure or vacuum 5 Cover the unit with a waterproof drop cloth if left outside all winter SEASONAL RESTART Before restarting your pool...

Страница 11: ...the displayed value UP KEY Increase the displayed value POOL HEATING MODE INDICATOR green indicates that the heat pump is heating the pool SPA HEATING MODE INDICATOR green indicates that the heat pum...

Страница 12: ...r displays OFF pool or spa Note regulator can be used to determine filtration time on a daily basis IMPORTANT Use this function ONLY if there is no external timer Filter timer wiring should be connect...

Страница 13: ...re sensor is not working or has been improperly connected HP3 will be displayed after having displayed HP on 3 occasions and heat pump will be shut off Correct water flow issue and perform regular bac...

Страница 14: ...odel or use more than one heat pump There is a lot of water under the device 1 Normal runoff due to condensation 2 Abnormal water leak 1 No action required install a drain if necessary 2 To determine...

Страница 15: ...mometer is often offset with respect to the graduations marked on the casing The thermometer displays temperatures higher or lower than the actual temperature of the water To measure the water tempera...

Страница 16: ...3 Damages caused by water flows below 57 liters per minute 15 US gallons and above 170 liters per minute 45 US gallons are not covered by this warranty 4 Damages caused by water pressure exceeding 2 b...

Страница 17: ...the time limits of this warranty the request must be authorized by our Customer Service Centre You can reach our Customer Service Department at 450 646 3960 during normal business hours or by internet...

Отзывы: