TTI Elite 100 Скачать руководство пользователя страница 3

 

 

WATER PRESSURE EQUIPMENT HAZARDS 

 

Your water filtration system works under pressure, and water pressure may go off prior to work 

beginning. Please refer to the water filtration system instruction manual for more information. 
 

PREVENTING INJURIES AND DROWNING 

 

To reduce the risk of injury, do not authorize children to operate this device.  

 

Do not allow anyone, and particularly children, to sit, climb or lean on any installed equipment 

that is part of your pool operation system. Unless otherwise specified, ALL components of your 
pool operation system should be at least 1 metre away from the pool so that children may not use 
them access the pool, which could result in injury or drowning. 

 

 

The thermodynamic and electrical specifications are outlined on the rating plate. 

 

Elite heat pumps have a 240V – 1 phase voltage. Make sure you have the appropriate electrical 

connections.  

 

Make sure that there is no watering or sprinkler system near or aimed at the water heater. Most 

water sprinkling systems are connected to wells whose water contains minerals, sulphur and other 
aggressive contaminants. These contaminants may promote corrosion and affect the efficiency of 
your heat pump.  

 

ELECTRICAL WARNINGS 

 

 

Installations should be performed by qualified professionals only. Any installation performed by 

another unqualified individual may entail risks for that individual and/or other people.  

 

Electrical installation should conform to the National Electrical Code as well as any provincial 

or municipal standards. 

 

KEEP ALL THESE INSTRUCTIONS 

 

 

 

 

 

WARNING 

Failure to heed the following warnings may result in damages 
to your pool equipment.

 

 

 

WARNING 

Avoir injuries cause by electrical current.

 

Содержание Elite 100

Страница 1: ...E 55 65 85 100 115 130 IMPORTANT It is important to register your product with us on our web site This will help us find your warranty when you place a service call If we cannot find your warranty reg...

Страница 2: ...r removing any Elite equipment make sure that all breakers covering the pool area have been turned off A clearly identified breaker must be installed in order to be able to interrupt power to the heat...

Страница 3: ...re outlined on the rating plate Elite heat pumps have a 240V 1 phase voltage Make sure you have the appropriate electrical connections Make sure that there is no watering or sprinkler system near or a...

Страница 4: ...inimum and maximum water flows IV CHLORINATORS BROMINATORS AND OTHERS P 8 9 Basic connections inline chlorinator or brominator Salt chlorinator Pressurized chlorinator or brominator Parallel connectio...

Страница 5: ...Your heat pump does not produce heat just like a water pump does not produce water with the energy it consumes Thus it is possible to achieve yields of up to 600 or 700 under optimum conditions or a...

Страница 6: ...clear any obstructions surrounding the heat pump as indicated in the table below ALL MODELS 1 in front of the evaporation coil 60 cm 2 feet 2 in front of all other surfaces 35 cm 14 inches 3 in front...

Страница 7: ...denser An adjustable automatic bypass valve must be installed when a water pump of 2 HP or more is used to circulate the pool water Your water pump must be able to supply each heat pump with a water f...

Страница 8: ...ot compliant to this rule SALT CHLORINATORS Salt chlorinators are made to be installed as inline chlorinators Therefore they must be installed as prescribed in the section above inline chlorinator or...

Страница 9: ...reaker must be installed close to the heat pump in an accessible location Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump If your he...

Страница 10: ...nse the condenser with tap water and drain the system with air pressure or vacuum 5 Cover the unit with a waterproof drop cloth if left outside all winter SEASONAL RESTART Before restarting your pool...

Страница 11: ...the displayed value UP KEY Increase the displayed value POOL HEATING MODE INDICATOR green indicates that the heat pump is heating the pool SPA HEATING MODE INDICATOR green indicates that the heat pum...

Страница 12: ...r displays OFF pool or spa Note regulator can be used to determine filtration time on a daily basis IMPORTANT Use this function ONLY if there is no external timer Filter timer wiring should be connect...

Страница 13: ...re sensor is not working or has been improperly connected HP3 will be displayed after having displayed HP on 3 occasions and heat pump will be shut off Correct water flow issue and perform regular bac...

Страница 14: ...odel or use more than one heat pump There is a lot of water under the device 1 Normal runoff due to condensation 2 Abnormal water leak 1 No action required install a drain if necessary 2 To determine...

Страница 15: ...mometer is often offset with respect to the graduations marked on the casing The thermometer displays temperatures higher or lower than the actual temperature of the water To measure the water tempera...

Страница 16: ...3 Damages caused by water flows below 57 liters per minute 15 US gallons and above 170 liters per minute 45 US gallons are not covered by this warranty 4 Damages caused by water pressure exceeding 2 b...

Страница 17: ...the time limits of this warranty the request must be authorized by our Customer Service Centre You can reach our Customer Service Department at 450 646 3960 during normal business hours or by internet...

Отзывы: