TTI Elite 100 Скачать руководство пользователя страница 2

 

 

FAILURE TO FOLLOW THESE INSTRUCTIONS 

WILL VOID YOUR WARRANTY 

MANDATORY SAFETY MEASURES 

Congratulations for your purchase of a Elite heat pump. Your new Elite heat pump will extend your 
pool season and bring you years of comfort and enjoyment. 

This document will help to answer any questions you may have, will provide technical support and 
will allow you to take full advantage of your new Elite heat pump safely. 

Please take the time to read this document in its entirety.  

IMPORTANT: YOUR HEAT PUMP MUST BE INSTALLED  

BY A CERTIFIED ELECTRICIAN. 

READ AND FOLLOW ALL INSTRUCTIONS. 

 

ELECTRICAL HAZARDS 

 

To reduce the risk of electrical shock: 

-

 

All electrical connections should be made by a licensed electrician in accordance with national, 

provincial and local codes and standards. 

-

 

Before installing or removing any Elite equipment, make sure that all breakers covering the pool 

area have been turned off.  

-

 

A clearly identified breaker must be installed in order to be able to interrupt power to the heat 

pump in case of an emergency. 

-

 

Never open the electrical box without having shut off all power sources to the heat pump 

beforehand.  

-

 

If your heat pump is equipped with a water pump control option, don’t forget to turn off the breaker 

for this pump prior to intervening.  

 
CHEMICAL HAZARDS 

 

Poorly balanced water may produce bacteria that can affect your health as well as damage your 

pool and its equipment. Have your water analyzed weekly by an expert. 

 

To avoid injury when using chemical products, wear rubber gloves and safety goggles, and work in 

a well-ventilated area. Choose wisely the area where you will be handling these chemicals, as they 
may damage any surface they come in contact with.  

 
 

 

 

WARNING

 

Failure to heed the following warnings may result in 
permanent injury, electrocution or drowning.

 

Содержание Elite 100

Страница 1: ...E 55 65 85 100 115 130 IMPORTANT It is important to register your product with us on our web site This will help us find your warranty when you place a service call If we cannot find your warranty reg...

Страница 2: ...r removing any Elite equipment make sure that all breakers covering the pool area have been turned off A clearly identified breaker must be installed in order to be able to interrupt power to the heat...

Страница 3: ...re outlined on the rating plate Elite heat pumps have a 240V 1 phase voltage Make sure you have the appropriate electrical connections Make sure that there is no watering or sprinkler system near or a...

Страница 4: ...inimum and maximum water flows IV CHLORINATORS BROMINATORS AND OTHERS P 8 9 Basic connections inline chlorinator or brominator Salt chlorinator Pressurized chlorinator or brominator Parallel connectio...

Страница 5: ...Your heat pump does not produce heat just like a water pump does not produce water with the energy it consumes Thus it is possible to achieve yields of up to 600 or 700 under optimum conditions or a...

Страница 6: ...clear any obstructions surrounding the heat pump as indicated in the table below ALL MODELS 1 in front of the evaporation coil 60 cm 2 feet 2 in front of all other surfaces 35 cm 14 inches 3 in front...

Страница 7: ...denser An adjustable automatic bypass valve must be installed when a water pump of 2 HP or more is used to circulate the pool water Your water pump must be able to supply each heat pump with a water f...

Страница 8: ...ot compliant to this rule SALT CHLORINATORS Salt chlorinators are made to be installed as inline chlorinators Therefore they must be installed as prescribed in the section above inline chlorinator or...

Страница 9: ...reaker must be installed close to the heat pump in an accessible location Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump If your he...

Страница 10: ...nse the condenser with tap water and drain the system with air pressure or vacuum 5 Cover the unit with a waterproof drop cloth if left outside all winter SEASONAL RESTART Before restarting your pool...

Страница 11: ...the displayed value UP KEY Increase the displayed value POOL HEATING MODE INDICATOR green indicates that the heat pump is heating the pool SPA HEATING MODE INDICATOR green indicates that the heat pum...

Страница 12: ...r displays OFF pool or spa Note regulator can be used to determine filtration time on a daily basis IMPORTANT Use this function ONLY if there is no external timer Filter timer wiring should be connect...

Страница 13: ...re sensor is not working or has been improperly connected HP3 will be displayed after having displayed HP on 3 occasions and heat pump will be shut off Correct water flow issue and perform regular bac...

Страница 14: ...odel or use more than one heat pump There is a lot of water under the device 1 Normal runoff due to condensation 2 Abnormal water leak 1 No action required install a drain if necessary 2 To determine...

Страница 15: ...mometer is often offset with respect to the graduations marked on the casing The thermometer displays temperatures higher or lower than the actual temperature of the water To measure the water tempera...

Страница 16: ...3 Damages caused by water flows below 57 liters per minute 15 US gallons and above 170 liters per minute 45 US gallons are not covered by this warranty 4 Damages caused by water pressure exceeding 2 b...

Страница 17: ...the time limits of this warranty the request must be authorized by our Customer Service Centre You can reach our Customer Service Department at 450 646 3960 during normal business hours or by internet...

Отзывы: