6. Abstract of LCD display
6-1. Spec of LCD display
16 characters and Two lines, LED back light (ON or OFF)
Displays "Count value: 0~4,294,967,295" , "Timer value: 0~1,099,511.62s".
It can display two items from the following 4 items into the two sections (upper row and lower row) by
the command via the communication line.
Count value, Timer value, Preset count value, Timer preset value
The view list items and LED back light status (on or off) are saved.
Display example 1 (upper line: count value, lower line: timer value)
C
N
T
0
1
0
0
0
0
0
0
0
0
0
0
T
I
M
E
R
0
0
0
0
0
0
0
.
0
0
Display example 2 (upper line: preset count value, lower line: timer preset value)
C
N
T
P
R
0
0
0
0
0
0
0
0
0
0
T
I
M
P
R
0
0
0
0
0
0
0
.
0
0
6-2. LCD display commands
Type of command
SDU00~17
To LCD upper line, it shows one of a count value from ch0 to ch17 .
CT08-ER2:CH8 is Encorder A,CH9 is Encorder B.
CT16-ER2:CH16 is Encorder A,CH17 is Encorder B.
SDUTM
To LCD upper line, it shows a timer value.
SDUCP
To LCD upper line, it shows a preset counter value.
SDUTP
To LCD upper line, it shows a timer preset value.
SDL00~17
To LCD lower line, it shows one of a count value from ch0 to ch17 .
CT08-ER2:CH8 is Encorder A,CH9 is Encorder B.
CT16-ER2:CH16 is Encorder A,CH17 is Encorder B.
SDLTM
To LCD lower line, it shows a timer value.
SDLCP
To LCD lower line, it shows a preset counter value.
SDLTP
To LCD lower line, it shows a timer preset value.
6-3.Backlight control commands
Type of command
BKON
Turn on the backlight
BKOFF
Turn off the backlight
6-4.Scalting function
You can use scalling function by setting scaling parameter.
Pulse counter and encorder counter is scaled by parameter (multiple , offset).
(Number of significant digits of the converted value is 15 digits)
Scaled value = (pulse-count + offset)×multiplier
parameters are set by communication commands.
・offset
0~±2147483647 (initial data:0)
・multiplier
±0.000001 ~ 999.999999 (initial data:1)
When multiplier is 1 and offset is 0, count value is not scaled.
In other paramter, display value is integer part 3 digits, the fractional part 6 digits.
Display example 1(upper line: encorder chA scaled value, lower line: encorder chB scaled value)
E
N
C
0
0
+
9
9
9
.
9
9
9
9
9
9
E
N
C
0
1
-
9
9
9
.
9
9
9
9
9
9
Display example 1(upper line: counter ch0 scaled value, lower line: counter ch1 scaled value)
C
N
T
0
0
+
9
9
9
.
9
9
9
9
9
9
C
N
T
0
1
-
9
9
9
.
9
9
9
9
9
9
37/43