![TSUJI ELECTRONICS CT08-ER2 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/tsuji-electronics/ct08-er2/ct08-er2_user-manual_1178497002.webp)
CT08-ER2~CT16-ER2 Command list (Available LAN,USB)
frequently used commands
ALM?
alarm read 0-15ch
read out the cause of overflow 0-15CH and timer
Reply: overXXXXTM or overXXXX--
read out the cause of overflow 0-xxCH and timer
ALMX?
alarm read extended to 0-xxch
Reply: overXXXXXXXXTM or
xx: 07 to 15
overXXXXXXXX--
CLAL
clear all
clear timer and all channel counters
CLPC
clear preset counter
clear preset counter (CH7)
CLTM
clear timer
clear timer
CLCTxx
clear counter xx
clear counter channel xx
xx:00-15
CLCTxxyy
clear counter xx to yy
clear counter channel xx to yy
xx、yy:00-15
CPR?
counter preset data read
read out preset counter data
Reply: 8 digits in dec (Kcts unit) (ex:00010000)
CPRF?
counter preset data read
read out preset counter data
Reply: 8 digits in dec (cts unit)
(ex:00010000)
CTMR?uuvvww
counter uu to vv and timer read
read out from channel uu to vv counter and timer
uu, vv:00-17
Reply: 10 digits in dec
ww: 00/no timer, 01/timer
CTMRH?uuvvww
counter uu to vv and timer read
read out from channel uu to vv counter and timer
uu, vv:00-17
Reply: 8 digits in hex
ww: 00/no timer, 01/timer
CTR?xx
counter xx read
read out channel xx counter
xx:00-17
Reply: 10 digits in dec
CTRH?xx
counter xx read
read out channel xx counter
xx:00-17
Reply: 8 digits in hex
CTR?xxyy
counter xx to yy read
read out channel xx counter
xx、yy:00-17
Reply: 10 digits in dec (separated by space)
CTRH?xxyy
counter xx to yy read
read out from channel xx to yy counter
xx、yy:00-17
Reply: 8 digits in hex (separated by space)
DSAS
disable auto stop
disable automatic stop until using STOP command
ENCS
enable counter stop
enable counter stop
ENTS
enable timer stop
enable timer stop
GATEIN_DS
gate in disable
gate in disable (counting, even if gate in)
GATEIN_EN
gate in enable
gate in enable (default)
GATEIN?
ask gate in mode
ask gate in mode reply : EN or DS
MOD?
mode read
read out counter mode
RDAL?
read all counter and timer
read out all counter and timer/Reply: 10 digits in dec
RDALH?
read all counter and timer
read out all counter and timer/Reply: 8 digits in hex
SCPRdddd・・・・
set counter preset data
set preset data to counter (Kcts unit)
SCPRFdddd・・・・
set counter preset data
set preset data to counter (cts unit)
TPR?
timer preset data read
read out preset timer data (ms unit)
TPRF?
timer preset data read
read out preset timer data (μs unit)
STOP
stop counter
deactivate counting action
STPRdddd・・・・
set preset counter to dddd・・・・
set preset timer value (ms unit)
STPRFdddd・・・・
set preset counter to dddd・・・・
set preset timer value (μs unit)
STRT
start counter
start counting action
TMR?
timer read
read out timer value Reply: 10 digits in dec
TMRH?
timer read
read out timer value Reply: 10 digits in hex
VER?
version information read
read out software version information
Reply: "1.00 11-11-11 CT08-ER2" (example)
VERH?
hardware version information
read out hardware version information
Reply: "HD-VER 1" (example)
REST
reset and start
set the unit restart (It's same as power on sequence)
FLG?x (x:0, 1, 2, 3)
read internal flag
read out internal state flag inside
COMMAND
FUNCTION
DETAIL
2/43