A-2
A
ERO
T
RAK
™ Portable Airborne Particle Counter
Specification
Description
Data Storage
10,000 sample records
Data Security
Password protected
Alarm/Status
Audible alarm on counts, and sensor status indicators
Alarm
This connector provides two pins for a contact closure
to control an external alarm. The contact closure is
normally open and rated for 0 to 60 V AC/DC at 1.5 A
peak, 0.5 A continuous. The “alarm out” is rated for
60 V insulation. The contact is closed under alarm
conditions determined by the programming of the
device.
Display
VGA 5.7-inch touch screen with Windows
®
CE
Languages
English, German, French, Spanish, Japanese, Chinese
(simplified), Italian
Reports
On screen viewable and printable ISO 14644-1,
FS-209E & EU GMP
Printer
Built-in thermal printer (also available without printer)
External Surface
Stainless Steel
AC Power (power to AC
adapter)
110 to 240 VAC universal power supply
DC Power (power to
instrument)
24 VDC @ 3.0 A
Battery
Removable/rechargeable Li-Ion (up to 2)
Battery Life
9310/9510: Up to 7 hours of continuous use
9350/9550: Up to 4 hours of continuous use
9500:
Up to 2 hours of continuous use
Recharge Time
4 hours (internal or external)
Dimensions (L x W x H) 24.1 x 23.0 x 23.2 (9.5 x 9.0 x 9.2)
Standards
CE, JIS B 9921, ISO 21501-4 as listed above
Weight
5.8 kg (12.8 lbs) with battery, 5.4 kg (11.8 lbs) without
battery
Warranty
2 years. Extended warranties available
Operating Conditions
5 to 35°C (41° to 95°F); 20% to 95% non-condensing
relative humidity
Storage Conditions
0 to 50°C (32 to 122°F); Up to 98% non-condensing
relative humidity
Included Accessories
Operating manual on CD, power cord, battery,
isokinetic probe, tripod, 3 m (10 ft) tubing, purge filter,
printer paper, USB cable, and T
RAK
P
RO
™ Lite data
download software
Optional Accessories
Electronic filter scanning probe, basic filter scanning
probe, TSI velocity probes, Temp/RH probe, additional
battery, dual port external battery charger, isokinetic
probes, isokinetic inlets, sample tubing, carrying case
Содержание 9510
Страница 2: ......
Страница 6: ......
Страница 18: ...1 6 AEROTRAK Portable Airborne Particle Counter This page intentionally left blank ...
Страница 62: ...3 30 AEROTRAK Portable Airborne Particle Counter The standard reports are shown below ...
Страница 72: ...5 4 AEROTRAK Portable Airborne Particle Counter This page intentionally left blank ...
Страница 76: ...6 4 AEROTRAK Portable Airborne Particle Counter This page intentionally left blank ...