28
7-11. Perform Zero Calibration
Command
ID 46 26 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
26
Spam zero calibration
00
Reserved code
Response
ID 46 26
00
(
CRC)
ID 46 26 ……Module command Line
00 : Reserved code
ID C6 00 (CRC)
ID C6 (CRC) C6:Error function code 00 : Reserved code
Example:
Send command :”01 46 26 00”,
Response:” 01 46 26 00”….Command valid,
Error Response: “01 C6 00 ”……Error code.
*Refer to paragraph 4 Function description before calibration.
7-12. Perform full Calibration
Command
ID 46 27 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
27
Spam full calibration
00
Reserved code
Response
ID 46 27
00
(
CRC)
ID 46 27 ……Module command Line
00 : Reserved code
ID C6 00 (CRC)
ID C6 (CRC) C6:Error function code 00 : Reserved code
Example:
Send command :”01 46 27 00”,
Response:” 01 46 27 00”….Command valid,
Error Response: “01 C6”……Error code.