7-3. Read the module’s configuration
Command ID 46 05 00 (CRC)
Syntax
Description
ID
Address of setting module 1~247
46
Function Code
05
Read module’s configuration
00
Reserved code
Response
ID 46 05 00
BD
00
TT
00
DF
00 00 (CRC)
ID 46 05 00 ……Module command Line
BD: Baud-Rate….See 7-3-2
TT: Analog Input type….See 7-3-1
DF: Data format….See 7-3-3
ID C6 00 (CRC)
ID C6 (CRC) C6:Error function code 00 : Reserved code
7-3-1. (TT) Analog input type
7-3-2. (BB) Baud Rate Setting
7-3-3. (DD) Data format setting
Example:
Type Code
08
09
0A
0B
0C
0D
Voltage:
±
10V
±5
V
±
2.5V
±
1.25V
±
650mV
±
20mA
% of FSR
±100 %
±100 %
±100 %
±100 %
±100 %
±100 %
2’S complement
HEX
0000~8000~FFFF
(HEX)
0000~8000~FFFF
(HEX)
0000~8000~FFFF
(HEX)
0000~8000~FFFF
(HEX)
0000~8000~FFFF
(HEX)
0000~8000~FFFF
(HEX)
Bit
7
6
5
4
3 2
1
0
Function
Rejection
*0=60Hz
1=50Hz
Checksum
*0:Disable
1:Enable
Mode
*0=Normal
1=Fast
0
0 0
Engineer Unit Format
*
00
=Voltage
01=Percent
10=2’s Complement HEX Format