background image

TRUST 240H EASY WEBSCAN GOLD 

4. 

Click on 'Next' to continue with the installation. 

5. 

Click on 'Yes’ to accept the license agreement and continue with the 
installation 

6. 

During the installation, a window will be displayed in which you must fill in 
some information, such as your name and your company name. Fill in this 
information and click on ‘Next’ to continue with the installation. 

Note

The installation will be stopped if you do not fill in a company 
name. Always give a company name. 

7. 

If desired, specify a location to install Photo Express in and click on ‘Next’. 

8. 

If desired, specify another location for the program icons and click on 'Next'. 

9. 

Click on 'Next' again. Photo Express will now be installed in the specified 
location. 

10. 

After the installation, click on ‘Finish’ to complete the installation process. 

You have now completed the installation of Ulead Photo Express 4.0 SE. After the 
installation, the Photo Express instruction manual can also be selected via the 
Windows Start menu by clicking on ‘Start – Programs - Ulead Photo Express 4.0 SE 
- Screenbook’. 

Note:

 

Adobe Acrobat Reader must be installed on your computer in 
order to read the Photo Express instruction manual. This 
program is included on the Ulead CD-ROM and the Trust CD-
ROM. On the Trust CD-ROM, open the ‘Acrobat’ folder and 
double-click on the ‘Setup.exe’ file. 

Continue to the next chapter. 

3.6 

Connecting the 240H Easy Webscan Gold to your 

computer 

Note:

 

A USB device is ‘hot-swappable’. This means that the device 
can be connected and disconnected from your computer whilst 
your computer is turned on. 

Note:

 

If you connect the scanner to a USB hub, then this hub must 
have its own power supply. The USB outputs must also provided 
a current of at least 500 mA. 

Note:

 

During installation in Windows 2000, you may receive a 
message saying that the driver has not been signed. This does 
not cause a problem for the functionality. 

Connect the scanner after the software has been installed. 
1. Start 

Windows. 

2. 

Connect one end of the USB cable to the scanner. 

3. 

Connect the other end of the USB cable to a free USB port on your 
computer. 

4. 

New hardware will be detected and the scanner will be automatically 
installed. 

Note: 

In Windows XP, select the option to manually search for the best 
driver and specify the location as [D:\WinXP]. ‘D:\’ is used to 
indicate your CD-ROM drive with the Trust CD-ROM containing 
the drivers and applications. 

Your scanner is now ready for use. 

Содержание 240H EASY WEBSCAN GOLD

Страница 1: ...uch of a button 2 Safety Carefully read the following instructions before use The TRUST 240H EASY WEBSCAN GOLD does not require any special maintenance Use a slightly damp soft cloth to clean the scan...

Страница 2: ...ing to unlock the scanner 1 Remove the scanner from the packaging and turn the scanner upside down 2 Use a small coin for example a five pence piece to unlock the transport lock by turning it anticloc...

Страница 3: ...the installation 4 Click on Install TextBridge Pro Millennium to continue with the installation 5 Click on Next 6 Select the option to accept the license agreement and click on Next 7 Fill in your nam...

Страница 4: ...computer in order to read the Photo Express instruction manual This program is included on the Ulead CD ROM and the Trust CD ROM On the Trust CD ROM open the Acrobat folder and double click on the Se...

Страница 5: ...ferent operating systems 5 Using the scanner Scans can be made in two different ways using the Trust 240H Easy Webscan Gold namely via the ScanPanel application the easiest way or via the TWAIN interf...

Страница 6: ...your default OCR application TextBridge Pro Millennium where the document is converted into a text file The text file can now be edited using a word processing program Exit Closes the ScanPanel applic...

Страница 7: ...IN window F Preview window Shows a preview scan of the image G Pixels Inch cm selection button Displays the width and height of the selected area in pixels inches or cm in the information window H H I...

Страница 8: ...if the TWAIN window has been opened from the application Send image to disk Saves the scanned image to your hard disk Send image to printer Sends the scanned image to the printer Send image to fax Sen...

Страница 9: ...Remove The properties of the area can be viewed by clicking on Property Calibrate scanner Calibrates the scanner Image Enhancement Tools Settings for improving the quality of the image Figure 6 will...

Страница 10: ...ion Reset monitor calibration Returns to the default settings 5 3 Making a scan Follow the instructions given below to make a scan also see figure 4 1 Place the image or document facing downwards on t...

Страница 11: ...it colours the TIF file format must be selected for File type C This is the only format which can handle 48 bit colours 8 Click on Acquire D to open the scanner s TWAIN interface window see figure 9 9...

Страница 12: ...ller which appears automatically when the application CD ROM is inserted into your CD ROM drive Also see the program s extensive Help function 6 Maintenance Regularly clean the glass plate with a soft...

Страница 13: ...ministrator before installing the scanner The USB port is switched off in the BIOS of your computer Consult the manual of your computer for switching on the USB port Windows does not detect any new ha...

Страница 14: ...ean the glass of the scanner thoroughly See chapter 6 Scanner is set to a very high resolution In practise a maximum resolution of 600dpi is sufficient Only use higher resolutions for small original i...

Страница 15: ...R result Resolution set too low Use a higher resolution when scanning the document Scanner does not function on a notebook Notebook battery voltage is insufficient for the USB scanner Use an external...

Отзывы: