3
17335
Code
Description
COPLA-40
Power Cord Grips used is: Type “Y”.
Tool Build Quality: Basic Insulation
Thermal insulation on motor winding: Class H
OUTPUT
INPUT
Current
22 A / 30 A
Frequency
60 Hz
Plasma Cutter
55 PSI -70 PSI
IP21S
IP Grade
Current Range
310 V c.c.
Open Circuit Voltage
1/2”
Maximum Cutting Capacity
Air Pressure
14.7 lb
Weight
3/8”
Ideal Cutting Capacity
35 % 3,5 minutes’ work per 6,5 minutes’ rest.
The specified output values are given in a 68 °F temperature.
With higher temperatures, the work cycle can be reduced.
Work Cycle
Insulation
Class I
110 V : 16 A / 220 V : 20 A - 40 A
12 AWG x 2 C with 221 °F insulation temperature
Conductors
3
Voltage (automatic adaptation)
110 V / 220 V
Technical specifications
ENGLISH
Power Requirements
In the event of faults or breakdown ground connection supplies a
minimum resistance trajectory for the power supply, thus reducing the risk of electric
shock. This tool is equipped with a power cable, adapter and ground connection
sockets. Ground shall be connected into an outlet installed and grounded following all
the local codes.
Do not modify the socket supplied. If the socket is not fit for
the outlet, have a certified electrician to install the appropriate outlet.
• If using the cutter together with more tools having the same ground, connect in parallel, never making a series.
• The ground conductor cable gauge shall not be a lower gauge than the power supply cable.
• Connection to the power supply shall be carried out by a professional electrician.
• Double check the input connection voltage shown in the plasma cutter nameplate matches the power
supply voltage.
• The power supply gauge
shall comply with the following requirements:
* Fuse fusion current is double than its rated current.
Switch
Fuse (rated working current)
Electric Wire
30 A
30 A (*)
2,5 mm
2
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
WARNING
CAUTION
CAUTION
CAUTION