Truper 15345 Скачать руководство пользователя страница 11

11

E

D

ENGLISH

Maintenance

Storing and Transportation

• When the generator has to be changing places turn OFF 

the motor switch and close the fuel tap.  Keep the 

generator leveled to prevent fuel spills.

• When storing the generator for long periods of time:

• Drain completely all the fuel of the generator as 

indicated in the previous chapter. Then, start the motor 

until all the fuel is eliminated from inside the motor.

• Replace oil as indicated in page 10.

• Remove the spark plug and pour a capful of 

SAE-10W-30 oil in the cylinder. Pull the jack-line in the 

starter to distribute the oil through the system. Then set 

the spark plug.

• Slowly pull the starter handle until feeling resistance. It 

indicates the cylinder is reaching the compression phase 

and the exhaust and absorption valves are closed.  

Storing the generator under these conditions prevents 

internal corrosion.

• Clean the generator with a damp cloth and cover it to 

prevent dust entering and build up.

• Store the generator in a clean, dry place away from 

children’s reach.

Fuel Drain

• Set under the tank and adequate container to receive 

gasoline. Use a funnel to prevent fuel from spilling.

• Having the fuel tap closed, remove and clean the fuel 

filter as indicated in page 10.

• Before setting the filter, open the fuel tap to drain all 

the fuel tank contents. Once drained, set the filter and 

sediment container.

• Set under the tank and adequate container to receive 

gasoline. Use a funnel to prevent fuel from spilling.

• Remove the drain bolt (

D

).

• Once the fuel is drained in the container, set the drain 

bolt back and washer.  Tighten firmly.

• Clean all fuel.

Spark Plug

• Before removing the spark plug (

E

) clean the area 

around the spark plug base to prevent dust and debris 

entering the motor. Then, remove the spark plug with the 

wrench included with the generator

 Clean the carbon deposits from the spark plug electrode. 

Use a spark plug cleaner or a wire brush.

• If the spark plug is damaged or worn, or reusing it is 

doubtful, replace with one identical.

• Measure the gap existing between the two electrodes.  

Use a spark plug gauge.  The distance between the center 

electrode and the lateral electrode shall measure between 

0.027” and 0.031”

• Check the spark plug washer is in good condition. Insert 

the spark plug manually to prevent a misadjusted position.

 After setting the spark plug, adjust with a spark plug 

spanner to compress the washer.

                          If installing a new spark plug, tighten up 

to half a turn after the spark plug is in place and the 

washer can pe compressed.   If installing a used spark 

plug, tighten up to 1/8 - 1/4 turn after the spark plug is in 

place and can compress the washer.

                              Improperly installed or out of range 

spark plugs, can get overheated and will damage the 

motor.

CAUTION

WARNING

Содержание 15345

Страница 1: ...Manual Power Generator GEN 80X Model Code GEN 80X Applies for 15345 15 Hp GEN 80X Motor CAUTION Read the user s manual thoroughly before operating this tool ENGLISH ESPA OL...

Страница 2: ...he best performance of the tool prolong the duty life make the Warranty valid if necessary and to avoid hazards of fatal injuries please read and understand this Manual before using the tool ENGLISH U...

Страница 3: ...dity may damage the motor fuel system when stored To prevent issues with the motor empty the fuel system before storing the generator during 30 days or longer periods of time Empty the gasoline tank s...

Страница 4: ...in the generator could damage the equipment or cause severe personal injuries to the operator Do not overreach Keep both feet perfectly set on the ground and keep good balance at all times These meas...

Страница 5: ...an shall carry out connections taking into account the differences between the power supply and the generator technical specifications Protection against electric shock depends on the circuit breakers...

Страница 6: ...and Connection Panel Control and Connection Panel 6 Electric generators made with one cylinder air cooled gasoline motor are a portable electric energy source for recreational use travel or camping fo...

Страница 7: ...or Check oil level before each use If necessary add oil until the level is within the limits in the cap oil measuring rod Replace oil after 50 hours operation In very dusty or dirty conditions it may...

Страница 8: ...ON position Motor Startup After starting the generator connect the required devices G to the contacts on the connection panel If you connect more than one device connect those that use a higher curren...

Страница 9: ...carried out Consult a Authorized Service Center to make the adjustments Operating in High Altitude Regular and careful maintenance es essential to keep the generator optimal security and performance l...

Страница 10: ...er a long period of time the sediment container needs to be cleaned With the motor OFF and ambient temperature close the fuel tap E Remove the sediment container F Clean the interior together with the...

Страница 11: ...l tap to drain all the fuel tank contents Once drained set the filter and sediment container Set under the tank and adequate container to receive gasoline Use a funnel to prevent fuel from spilling Re...

Страница 12: ...2 Remove the drain bolt Fuel shall flow freely Otherwise go to a Authorized Service Center Verify spark in the spark plug 1 Disconnect the spark plug cable Clean the dust around the spark plug and re...

Страница 13: ...oid 0 0 Brown E G FS BAT ST JG Engine switch Orange Orange DC winding Protector Black Black White White Orange Green Yellow Green Red Black Panel section Motor section Power section DC 12 DC 12 Ground...

Страница 14: ...14 Notes ENGLISH...

Страница 15: ...NTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO D...

Страница 16: ...onnel not authorized by Truper To make the warranty valid present the product stamped policy or invoice or receipt or voucher in the establishment where you bought it or in Corregidora 22 Centro Cuauh...

Страница 17: ...L ENGLISH Instructivo de Generador el ctrico GEN 80X Modelo C digo GEN 80X Este instructivo es para 15345 15 Hp Motor GEN 80X 11 200 W Lea este Instructivo por completo antes de usar la herramienta AT...

Страница 18: ...tencias de Seguridad para uso de generadores el ctricos Partes Combustible y aceite Puesta en marcha Mantenimiento Soluci n de problemas Diagrama el ctrico Notas Centros de Servicio Autorizados P liza...

Страница 19: ...o gasohol etanol o metano ya que pueden atraer humedad la cual provoca la separaci n y la formaci n de cidos durante el almacenaje La acidez puede da ar el sistema de combustible del motor cuando se e...

Страница 20: ...tes rotativas del generador pueden causar da os al equipo o al operador No sobrepase su campo de acci n Mantenga ambos pies bien asentados sobre el suelo y conserve el equilibrio en todo momento Esto...

Страница 21: ...cias de Seguridad para uso de generadores el ctricos Nunca fume cerca del combustible ni de la zona en donde se abastezca de la gasolina ni al operar el generador Para reducir el riesgo de incendio o...

Страница 22: ...mbustible Filtro de aire Panel de control y conexi n Panel de control y conexi n 6 Partes Los generadores el ctricos con motor a gasolina de un cilindro enfriados por aire son una fuente de energ a el...

Страница 23: ...ue el nivel se encuentre entre los l mites de la varilla del tap n Cambie el aceite despu s de 50 horas de operaci n En condiciones de mucho polvo o suciedad puede ser necesario hacer el cambio de ace...

Страница 24: ...Arranque del motor Despu s de haber arrancado el generador conecte los dispositivos que necesite G en los contactos del panel de conexi n Si conecta m s de un dispositivo conecte primero los que utili...

Страница 25: ...m 1000 pies arriba de 2100 m 6890 pies sobre el nivel del mar La disminuci n de potencia ser m s dr stica si no se realizan ajustes al carburador Consulte a un Centro de Servicio Autorizado para real...

Страница 26: ...e debe estar entre las marcas m nimo y m ximo de la varilla Aseg rese de que el nivel no exceda la marca de m ximo Apriete el tap n del tanque cuando el nivel sea el adecuado Arranque el motor y permi...

Страница 27: ...nar todo el contenido del tanque de combustible Una vez drenado coloque el filtro y el contenedor de sedimentos Coloque debajo del carburador un contenedor adecuado para recibir gasolina y utilice un...

Страница 28: ...buj a 1 Desconecte el cable de la buj a limpie el polvo alrededor de la buj a y ret rela 2 Conecte el cable a la buj a 3 Encienda el interruptor del motor 4 Ponga en contacto el electrodo central de...

Страница 29: ...af E G FS BAT ST JG Interruptor del motor Devanado D C Protector Negro Negro Blanco Blanco O Verde Amarillo Verde Rojo Negro Secci n del panel Secci n del motor Secci n de pontencia DC 12 DC 12 Tierra...

Страница 30: ...14 Notas ESPA OL...

Страница 31: ...0 88 CENTRO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL...

Страница 32: ...o reparado por personal no autorizado por Truper Para hacer efectiva la garant a presente el producto p liza sellada o factura o recibo o comprobante en el establecimiento donde lo compr o en Corregid...

Отзывы: