background image

10

Minimum

Maximum

C

A

B

E

E

F

G

H

Air filter

ENGLISH

Maintenance

• Check the air filter to assure is in good conditions.  

Remember, a dirty filter could cause start up issues, loss 

of performance and shorten the useful life of the motor.

• Remove the air filter cover releasing the locks (

A

).

• Wash the filter with a hot water and detergent solution. 

allow the filter to dry completely.

• Soak the filter in clean SAE-20 motor oil. Squeeze until 

eliminating the excessive oil. The motor might release 

smoke during start up if there is too much oil in the filter.

• Install the filter in its container and set the cover back in 

place.

                          Never use gasoline to clean the air filter. 

It could cause a fire or explosion. Never start the 

generator with no air filter in place. The motor wears out 

faster.

Air Filter

• The fuel filter stops water and dust present in the fuel 

tank, get inside the carburetor.  If the motor has not 

been started after a long period of time, the sediment 

container needs to be cleaned:

• With the motor OFF and ambient temperature, close 

the fuel tap (

E

).

• Remove the sediment container (

F

). Clean the interior 

together with the filter (

G

).

• Leave the filter and container drying completely.

• Verify the washer (

H

) is in good conditions. Set the 

sediment container and fuel filter back in place.

Fuel Filter

Oil Change

• The oil drain cap is set under the motor (

B

).

• Set an adequate container under the generator to get 

the oil.  Remove the drain cap and then, the tank cap 

(

C

). Once the oil is drained, set back the drain cap.

• Clean any spills or splashes.

• Fill up the tank with SAE-10W-30 oil.

• Check oil level setting the oil tank cap without screwing 

it. Oil level shall be between the 

minimum

 and 

maximum

 level in the oil measuring rod.  Make sure the 

level is not exceeding the 

maximum

 mark. Tighten the 

tank cap when the level is adequate.

• Start the motor and leave it running briefly.  Stop the 

motor. Wait one minute and check the oil level again.  

Refill if necessary.

• For no reason at all pour used oil in the drain! Take 

the used oil to a recycling unit.

CAUTION

Содержание 15345

Страница 1: ...Manual Power Generator GEN 80X Model Code GEN 80X Applies for 15345 15 Hp GEN 80X Motor CAUTION Read the user s manual thoroughly before operating this tool ENGLISH ESPA OL...

Страница 2: ...he best performance of the tool prolong the duty life make the Warranty valid if necessary and to avoid hazards of fatal injuries please read and understand this Manual before using the tool ENGLISH U...

Страница 3: ...dity may damage the motor fuel system when stored To prevent issues with the motor empty the fuel system before storing the generator during 30 days or longer periods of time Empty the gasoline tank s...

Страница 4: ...in the generator could damage the equipment or cause severe personal injuries to the operator Do not overreach Keep both feet perfectly set on the ground and keep good balance at all times These meas...

Страница 5: ...an shall carry out connections taking into account the differences between the power supply and the generator technical specifications Protection against electric shock depends on the circuit breakers...

Страница 6: ...and Connection Panel Control and Connection Panel 6 Electric generators made with one cylinder air cooled gasoline motor are a portable electric energy source for recreational use travel or camping fo...

Страница 7: ...or Check oil level before each use If necessary add oil until the level is within the limits in the cap oil measuring rod Replace oil after 50 hours operation In very dusty or dirty conditions it may...

Страница 8: ...ON position Motor Startup After starting the generator connect the required devices G to the contacts on the connection panel If you connect more than one device connect those that use a higher curren...

Страница 9: ...carried out Consult a Authorized Service Center to make the adjustments Operating in High Altitude Regular and careful maintenance es essential to keep the generator optimal security and performance l...

Страница 10: ...er a long period of time the sediment container needs to be cleaned With the motor OFF and ambient temperature close the fuel tap E Remove the sediment container F Clean the interior together with the...

Страница 11: ...l tap to drain all the fuel tank contents Once drained set the filter and sediment container Set under the tank and adequate container to receive gasoline Use a funnel to prevent fuel from spilling Re...

Страница 12: ...2 Remove the drain bolt Fuel shall flow freely Otherwise go to a Authorized Service Center Verify spark in the spark plug 1 Disconnect the spark plug cable Clean the dust around the spark plug and re...

Страница 13: ...oid 0 0 Brown E G FS BAT ST JG Engine switch Orange Orange DC winding Protector Black Black White White Orange Green Yellow Green Red Black Panel section Motor section Power section DC 12 DC 12 Ground...

Страница 14: ...14 Notes ENGLISH...

Страница 15: ...NTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL CENTRO C P 43600 TULANCINGO HGO TEL 775 753 6615 775 753 6616 SUCURSAL GUADALAJARA AV ADOLFO B HORN 6800 COL SANTA CRUZ DEL VALLE C P 45655 TLAJOMULCO D...

Страница 16: ...onnel not authorized by Truper To make the warranty valid present the product stamped policy or invoice or receipt or voucher in the establishment where you bought it or in Corregidora 22 Centro Cuauh...

Страница 17: ...L ENGLISH Instructivo de Generador el ctrico GEN 80X Modelo C digo GEN 80X Este instructivo es para 15345 15 Hp Motor GEN 80X 11 200 W Lea este Instructivo por completo antes de usar la herramienta AT...

Страница 18: ...tencias de Seguridad para uso de generadores el ctricos Partes Combustible y aceite Puesta en marcha Mantenimiento Soluci n de problemas Diagrama el ctrico Notas Centros de Servicio Autorizados P liza...

Страница 19: ...o gasohol etanol o metano ya que pueden atraer humedad la cual provoca la separaci n y la formaci n de cidos durante el almacenaje La acidez puede da ar el sistema de combustible del motor cuando se e...

Страница 20: ...tes rotativas del generador pueden causar da os al equipo o al operador No sobrepase su campo de acci n Mantenga ambos pies bien asentados sobre el suelo y conserve el equilibrio en todo momento Esto...

Страница 21: ...cias de Seguridad para uso de generadores el ctricos Nunca fume cerca del combustible ni de la zona en donde se abastezca de la gasolina ni al operar el generador Para reducir el riesgo de incendio o...

Страница 22: ...mbustible Filtro de aire Panel de control y conexi n Panel de control y conexi n 6 Partes Los generadores el ctricos con motor a gasolina de un cilindro enfriados por aire son una fuente de energ a el...

Страница 23: ...ue el nivel se encuentre entre los l mites de la varilla del tap n Cambie el aceite despu s de 50 horas de operaci n En condiciones de mucho polvo o suciedad puede ser necesario hacer el cambio de ace...

Страница 24: ...Arranque del motor Despu s de haber arrancado el generador conecte los dispositivos que necesite G en los contactos del panel de conexi n Si conecta m s de un dispositivo conecte primero los que utili...

Страница 25: ...m 1000 pies arriba de 2100 m 6890 pies sobre el nivel del mar La disminuci n de potencia ser m s dr stica si no se realizan ajustes al carburador Consulte a un Centro de Servicio Autorizado para real...

Страница 26: ...e debe estar entre las marcas m nimo y m ximo de la varilla Aseg rese de que el nivel no exceda la marca de m ximo Apriete el tap n del tanque cuando el nivel sea el adecuado Arranque el motor y permi...

Страница 27: ...nar todo el contenido del tanque de combustible Una vez drenado coloque el filtro y el contenedor de sedimentos Coloque debajo del carburador un contenedor adecuado para recibir gasolina y utilice un...

Страница 28: ...buj a 1 Desconecte el cable de la buj a limpie el polvo alrededor de la buj a y ret rela 2 Conecte el cable a la buj a 3 Encienda el interruptor del motor 4 Ponga en contacto el electrodo central de...

Страница 29: ...af E G FS BAT ST JG Interruptor del motor Devanado D C Protector Negro Negro Blanco Blanco O Verde Amarillo Verde Rojo Negro Secci n del panel Secci n del motor Secci n de pontencia DC 12 DC 12 Tierra...

Страница 30: ...14 Notas ESPA OL...

Страница 31: ...0 88 CENTRO DE SERVICIO ECLIPSE CALLE PRINCIPAL MZ 1 LT 1 COL SANTA FE C P 39010 CHILPANCINGO GRO TEL 747 478 5793 FERREPRECIOS S A DE C V LIBERTAD ORIENTE 304 LOCAL 30 INTERIOR DE PASAJE ROBLEDO COL...

Страница 32: ...o reparado por personal no autorizado por Truper Para hacer efectiva la garant a presente el producto p liza sellada o factura o recibo o comprobante en el establecimiento donde lo compr o en Corregid...

Отзывы: