background image

4

Obligations of the operator / vehicle owner

The vehicle owner is responsible for cor-
rect operation of the appliance.

The installer or vehicle owner must affix 
the yellow warning information sticker 

that is provided with the appliance to the ve-
hicle in a location that is clearly visible to all 
users. Missing stickers can be requested from 
Truma.

The appliance, the gas system and the 
exhaust duct for the combustion prod-

ucts must be inspected by a recognised expert 
in accordance with the national regulations 
(e.g. DVGW Worksheet G 607 in Germany) or, 
if there are no such regulations, at least every 
two years. 

 

– A recognised specialist must carry out a leak 

test after changes have been made to the 
liquid gas system.

 

– The vehicle owner is responsible for having 

the check carried out.

Pressure regulating devices and hoses 
must be replaced with new ones no 

more than 10 years after their date of manu-
facture (every 8 years if used commercially).

 

Inspect hose lines regularly and have 
them replaced if they are broken.

Safe operation

The use of upright gas cylinders from 
which gas is taken in the 

gas phase

 is 

mandatory for the operation of gas pressure 
regulation systems, gas equipment and gas 
systems. Gas cylinders from which gas is tak-
en in the liquid phase (e. g. for fork lifts) must 
not be used, since they would result in dam-
age to the gas system.

The operating pressure of the gas supply 
(30 mbar) and of the appliance (see type 

plate) must be the same.

In Germany, only pressure regulating equip-
ment that complies with DIN EN 16129 

(in vehicles) with a fixed output pressure of 
30 mbar may be used for the gas system. The 
flow rate of the pressure regulating equipment 
must correspond to at least the maximum 
consumption of all appliances installed by the 
system manufacturer.

For vehicles, we recommend the Truma 
MonoControl CS gas pressure regula-

tion system and the Truma DuoComfort / 
 DuoControl CS gas pressure regulation sys-
tem for two-cylinder gas systems.

 

At temperatures of around 0 °C and be-
low, the gas pressure regulation system 

or the changeover valve should be operated 
with the EisEx regulator heater.

Suitable hoses that meet national regula-
tions must always be used in the respec-

tive destination country.

 

During the initial start-up of a brand new 
appliance, small quantities of fumes and 

a slight odour may briefly occur. When the ap-
pliance is started up after a particularly long 
period of non-use, there may be some smoke 
and/or smell due to dust or dirt. It is a good 
idea to allow the appliance to run at maximum 
output for a few minutes for the purpose of 
self-cleaning and to ensure that the area is 
well ventilated.

This appliance may be used by children 
from 8 years old and by persons with 

reduced physical, sensory or mental capabili-
ties or with a lack of experience only if they 
are supervised or have been instructed in the 
safe use of the appliance and understand the 
resulting risks.

Children must not be allowed to play 
with the appliance.

The integrity and tight fit of the exhaust 
double duct must be checked regularly, 

particularly at the end of long trips. Also check 
the mounting of the appliance and the cowl.

To prevent damage to the appliance 
from spray water, such as when cleaning 

the vehicle, do not spray water directly into 
the cowl.

Содержание VarioHeat

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle Truma VarioHeat...

Страница 2: ...lid laws di rectives and standards must be observed Not following the rules in the operating and installation instructions can result in serious material damage and can seriously put at risk the healt...

Страница 3: ...appliance must not be operated during refuelling the vehicle the caravan s towing vehicle or other appliances Switch off the LP gas appliance at the control panel Shut off the gas supply to the LP ga...

Страница 4: ...vehicles with a fixed output pressure of 30 mbar may be used for the gas system The flow rate of the pressure regulating equipment must correspond to at least the maximum consumption of all appliance...

Страница 5: ...s supply and switch off the appliance Danger of fire explosion if you attempt to use an appliance that has been dam aged by flooding or if the vehicle has been involved in an accident A damaged applia...

Страница 6: ...plus VarioHeat control panel is used to control and monitor a Truma VarioHeat heater and or a Truma air conditioning system The following air conditioning systems can be operated with the Truma CP pl...

Страница 7: ...nu item Service menu RESET PR SET After confirmation the Truma CP plus VarioHeat control panel initialises itself INIT appears on the display while this is in progress The appliances that have been fo...

Страница 8: ...conditioning system is in heating mode e VENT Air conditioning system is in air circulation mode Quick temperature change possible using rotary push button in stand by screen Select fan level With con...

Страница 9: ...rotary push button 24 h mode 12 h mode Figure 12 a m p m Figure 13 If the start end point was exceeded during entry the op erating parameters are not taken into consideration until the next start end...

Страница 10: ...or of the heater OFFSET The room temperature sensor of the heater can be individu ally adjusted to the sensor s installation situation The set ting can be made in increments of 0 5 C within the range...

Страница 11: ...ing parameter is within the target range again this symbol goes off again automatically Figure 30 Read out code of warning Select icon with rotary push button Tap the rotary push button The current wa...

Страница 12: ...control knob When the appliance is on heating or ventilation the green LED must light up the fan is on If the LED does not light up check the main switch if necessary Please observe the respective ve...

Страница 13: ...12 V Truma VarioHeat eco 0 65 2 75 A Truma VarioHeat comfort 0 65 2 75 5 4 A Quiescent current consumption with Truma CP plus VarioHeat 0 004 A with Truma CP classic VarioHeat 0 001 A Weight Heater w...

Страница 14: ...ll also be applicable 2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with t...

Страница 15: ...blocked End outlets EN closed up Remove blockage Remove blockage Open end outlets EN 28 Open window above cowl window switch Close windows 29 Risk of low voltage battery voltage too low 10 4 V Charge...

Страница 16: ...osed Gas cylinder empty Gas pressure regulation system iced up Butane content in the gas cylinder too high Combustion air infeed or exhaust outlet is sealed Check gas supply and open valves Replacing...

Страница 17: ...vice partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate Truma Ger tetechnik GmbH Co KG Wernher von Braun Stra e 12 85640 Putzbrunn De...

Отзывы: