background image

5

Operation while driving

For heating while driving, the UN ECE regula-
tion 122 stipulates a safety shut-off device to 
prevent the uncontrolled escape of gas in the 
event of an accident. The Truma MonoControl 
CS gas pressure regulation system fulfils this 
requirement. National regulations and rules 
must be followed.

If no safety shut-off device (e.g. no 
 MonoControl CS) is installed, the gas cylin-
der must be closed while driving and notices 
must be attached in accordance with the 
valid regulations.

Troubleshooting

If you notice unusual noises or smells, 
close off the gas supply and switch off 

the appliance.

Danger of fire / explosion if you attempt 
to use an appliance that has been dam-

aged by flooding or if the vehicle has been 
involved in an accident. A damaged appliance 
must be repaired by an expert or be replaced.

Have faults repaired by an expert with-
out delay.

Only carry out repairs yourself if the so-
lution is described in the troubleshooting 

guide of this operating instructions.

Following a deflagration (backfire), have 
the appliance and the exhaust gas sys-

tem checked by an expert.

Maintenance / Repairs / Cleaning

The appliance may only be maintained, 
repaired and cleaned by an expert. 

Maintenance, repairs and cleaning must 
not be done by children.

It is prohibited to use products contain-
ing chlorine on and inside the appliance.

Содержание VarioHeat

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle Truma VarioHeat...

Страница 2: ...lid laws di rectives and standards must be observed Not following the rules in the operating and installation instructions can result in serious material damage and can seriously put at risk the healt...

Страница 3: ...appliance must not be operated during refuelling the vehicle the caravan s towing vehicle or other appliances Switch off the LP gas appliance at the control panel Shut off the gas supply to the LP ga...

Страница 4: ...vehicles with a fixed output pressure of 30 mbar may be used for the gas system The flow rate of the pressure regulating equipment must correspond to at least the maximum consumption of all appliance...

Страница 5: ...s supply and switch off the appliance Danger of fire explosion if you attempt to use an appliance that has been dam aged by flooding or if the vehicle has been involved in an accident A damaged applia...

Страница 6: ...plus VarioHeat control panel is used to control and monitor a Truma VarioHeat heater and or a Truma air conditioning system The following air conditioning systems can be operated with the Truma CP pl...

Страница 7: ...nu item Service menu RESET PR SET After confirmation the Truma CP plus VarioHeat control panel initialises itself INIT appears on the display while this is in progress The appliances that have been fo...

Страница 8: ...conditioning system is in heating mode e VENT Air conditioning system is in air circulation mode Quick temperature change possible using rotary push button in stand by screen Select fan level With con...

Страница 9: ...rotary push button 24 h mode 12 h mode Figure 12 a m p m Figure 13 If the start end point was exceeded during entry the op erating parameters are not taken into consideration until the next start end...

Страница 10: ...or of the heater OFFSET The room temperature sensor of the heater can be individu ally adjusted to the sensor s installation situation The set ting can be made in increments of 0 5 C within the range...

Страница 11: ...ing parameter is within the target range again this symbol goes off again automatically Figure 30 Read out code of warning Select icon with rotary push button Tap the rotary push button The current wa...

Страница 12: ...control knob When the appliance is on heating or ventilation the green LED must light up the fan is on If the LED does not light up check the main switch if necessary Please observe the respective ve...

Страница 13: ...12 V Truma VarioHeat eco 0 65 2 75 A Truma VarioHeat comfort 0 65 2 75 5 4 A Quiescent current consumption with Truma CP plus VarioHeat 0 004 A with Truma CP classic VarioHeat 0 001 A Weight Heater w...

Страница 14: ...ll also be applicable 2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with t...

Страница 15: ...blocked End outlets EN closed up Remove blockage Remove blockage Open end outlets EN 28 Open window above cowl window switch Close windows 29 Risk of low voltage battery voltage too low 10 4 V Charge...

Страница 16: ...osed Gas cylinder empty Gas pressure regulation system iced up Butane content in the gas cylinder too high Combustion air infeed or exhaust outlet is sealed Check gas supply and open valves Replacing...

Страница 17: ...vice partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate Truma Ger tetechnik GmbH Co KG Wernher von Braun Stra e 12 85640 Putzbrunn De...

Отзывы: