background image

12

Maintenance

The Truma CP plus VarioHeat control panel is maintenance-

free. In order to clean the front panel, use a damp, non-scour-

ing cloth. If this is not sufficient, use a neutral soap solution.

Truma CP classic VarioHeat analogue 

control panel (optional)

         

VarioHeat 

d

c

e

1

3

5

7

9

1

2

3


5

a

b

Figure 33

a  = “Heating” control knob 

    Green LED “Operation” 

    Red LED “Fault / Warning”

b = Rotary switch 

c  = “Heating” rotary switch 

Large flame symbol “eco”

    Small flame symbol “night”

d = Rotary switch “Off”

e  = Rotary switch “Vent” 

Full load (large symbol)  

 

Partial load (small symbol)

eco

Automatic control of the fan, depending on the heating power 

/ optimised to the current heating requirement

night

Heater running only at partial load. Might not be possible to 

reach the set room temperature (depending on the vehicle 

size and outside temperature).

Switch the heater on

 

– Set the desired room temperature at the control knob (a).

 

– Set the rotary switch (b) to the desired output (c).

Switch the ventilation on

 

– Set the rotary switch (b) to the desired output (e).

Switching off

Set the rotary switch (b) to the centre (d). If the heater is 

turned off after heating, the fan may still run to utilise the re-

sidual heat.

Green LED “On”

(beneath control knob)

When the appliance is on (heating or ventilation), the green 

LED must light up (the fan is on). If the LED does 

not

 light 

up, check the (main) switch if necessary. Please observe the 

respective vehicle manufacturer’s instructions.

Red LED “Fault / warning”

If there is a fault / warning, the red LED flashes. In each case, 

the fault is reset by switching off and then switching back on 

again. Following a reset, it can take some time until the green 

LED lights up again.

A flashing code is output in the event of a fault / warning.  

The 

Truma CP classic VarioHeat troubleshooting guide

  

enables the cause and remedy to be determined.

Maintenance

The Truma CP classic VarioHeat control panel is maintenance-

free. In order to clean the front panel, use a damp, non-scour-

ing cloth. If this is not sufficient, use a neutral soap solution.

Disposing of the VarioHeat

The appliance must be disposed of in accordance with the ad-

ministrative regulations of the respective country in which it is 

used. National regulations and laws (in Germany, for example, 

the End-of-Life Vehicle Regulation) must be observed.

VarioHeat fuse

The appliance fuse is located on the electronic control unit 

and can only be changed by an expert.

Appliance fuse (F1):  

10 AF – quick – (EN 60127-2-3) 

The fine wire fuse must always be replaced with a fuse of the 

same type.

Accessories

Cowl cover

39141-00 cream

39141-01 black

39141-02 bianco

Содержание VarioHeat

Страница 1: ...Operating instructions Page 2 To be kept in the vehicle Truma VarioHeat...

Страница 2: ...lid laws di rectives and standards must be observed Not following the rules in the operating and installation instructions can result in serious material damage and can seriously put at risk the healt...

Страница 3: ...appliance must not be operated during refuelling the vehicle the caravan s towing vehicle or other appliances Switch off the LP gas appliance at the control panel Shut off the gas supply to the LP ga...

Страница 4: ...vehicles with a fixed output pressure of 30 mbar may be used for the gas system The flow rate of the pressure regulating equipment must correspond to at least the maximum consumption of all appliance...

Страница 5: ...s supply and switch off the appliance Danger of fire explosion if you attempt to use an appliance that has been dam aged by flooding or if the vehicle has been involved in an accident A damaged applia...

Страница 6: ...plus VarioHeat control panel is used to control and monitor a Truma VarioHeat heater and or a Truma air conditioning system The following air conditioning systems can be operated with the Truma CP pl...

Страница 7: ...nu item Service menu RESET PR SET After confirmation the Truma CP plus VarioHeat control panel initialises itself INIT appears on the display while this is in progress The appliances that have been fo...

Страница 8: ...conditioning system is in heating mode e VENT Air conditioning system is in air circulation mode Quick temperature change possible using rotary push button in stand by screen Select fan level With con...

Страница 9: ...rotary push button 24 h mode 12 h mode Figure 12 a m p m Figure 13 If the start end point was exceeded during entry the op erating parameters are not taken into consideration until the next start end...

Страница 10: ...or of the heater OFFSET The room temperature sensor of the heater can be individu ally adjusted to the sensor s installation situation The set ting can be made in increments of 0 5 C within the range...

Страница 11: ...ing parameter is within the target range again this symbol goes off again automatically Figure 30 Read out code of warning Select icon with rotary push button Tap the rotary push button The current wa...

Страница 12: ...control knob When the appliance is on heating or ventilation the green LED must light up the fan is on If the LED does not light up check the main switch if necessary Please observe the respective ve...

Страница 13: ...12 V Truma VarioHeat eco 0 65 2 75 A Truma VarioHeat comfort 0 65 2 75 5 4 A Quiescent current consumption with Truma CP plus VarioHeat 0 004 A with Truma CP classic VarioHeat 0 001 A Weight Heater w...

Страница 14: ...ll also be applicable 2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with t...

Страница 15: ...blocked End outlets EN closed up Remove blockage Remove blockage Open end outlets EN 28 Open window above cowl window switch Close windows 29 Risk of low voltage battery voltage too low 10 4 V Charge...

Страница 16: ...osed Gas cylinder empty Gas pressure regulation system iced up Butane content in the gas cylinder too high Combustion air infeed or exhaust outlet is sealed Check gas supply and open valves Replacing...

Страница 17: ...vice partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate Truma Ger tetechnik GmbH Co KG Wernher von Braun Stra e 12 85640 Putzbrunn De...