EQUIPMENT DET
AILS
110
Operation with on-board
12 v power supply
Indicator
Fault
Remedy
(2) and (8)
flashing and acous-
tic signal 20s
230 V mode:
"230V" not avail-
able or voltage too
low
Check mains power connection, mains voltage,
fuse
(4) and (8)
flashing and acous-
tic signal 20s
12 V mode:
"12V" not available
or voltage too low
Check 12V connection, on-board battery, fuse
(3) and (8)
flashing and acous-
tic signal 20s
Gas mode:
Flame not ignited
Check gas supply (gas bottle, gas valve)
Press the
(8)
button after clearing the fault
Acoustic signal,
15s at two minute
intervals
Interior lighting is
switched on
Close door, check door contact
(2) and (7)
flashing and acous-
tic signal 20s
230 V mode:
230V heating ele-
ment defective
Arrange replacement of 230V heating element,
contact Customer Service
(4) and (7)
flashing and acous-
tic signal 20s
12 V mode:
12V heating ele-
ment defective
Arrange replacement of 12V heating element,
contact Customer Service
(7)
flashing and acous-
tic signal 20s
Temperature sensor
without contact or
defective
Contact Customer Service
(3) and (7)
flashing and acous-
tic signal 20s
Burner defective
or cooling unit
defective
Check burner, burner nozzles, if
necessary contact Customer Service and
arrange replacement