background image

30

www

.

truemfg

.

com

THIS WARRANTY ONLY APPLIES TO UNITS SHIPPED FROM TRUE’S MANUFACTURING FACILITIES AFTER JULY 1, 2014.

THREE YEAR PARTS & LABOR WARRANTY

ADDITIONAL TWO YEAR  COMPRESSOR WARRANTY

404A/134A  COMPRESSOR WARRANTY

WARRANTY CLAIMS

WHAT IS NOT COVERED BY THIS WARRANTY

TRUE warrants to the original purchaser of every new TRUE refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal and 
proper use and maintenance service as specified by TRUE and upon proper installation and start-up in accordance with the instruction packet supplied with each TRUE unit.  TRUE’s 
obligation under this warranty is limited to a period of three (3) years from the date of original installation or 39 months after shipment date from TRUE, whichever occurs first.
Any part covered under this warranty that are determined by TRUE to have been defective within three (3) years of original installation or thirty-nine (39) months after shipment date 
from manufacturer, whichever occurs first, is limited to the repair or replacement, including labor charges, of defective parts or assemblies.  The labor warranty shall include standard straight 
time labor charges only and reasonable travel time, as determined by TRUE.
Warranty does not cover standard wear parts which include door gaskets, incandescent bulbs or fluorescent bulbs.  Warranty also does not cover issues caused by improper installation 
or lack of basic preventative maintenance which includes regular cleaning of condenser coils.

In addition to the Three (3) year warranty stated above, TRUE warrants its hermetically and semi-hermetically sealed compressor to be free from defects in both material and workman-
ship under normal and proper use and maintenance service for a period of two (2) additional years from the date of original installation but not to exceed five (5) years and three (3) 
months after shipment from the manufacturer.
Compressors determined by TRUE to have been defective within this extended time period will, at TRUE’s option, be either repaired or replaced with a compressor or compressor parts 
of similar design and capacity.
The two (2) year extended compressor warranty applies only to hermetically and semi-hermetically sealed parts of the compressor and does not apply to any other parts or components, 
including, but not limited to: cabinet, paint finish, temperature control, refrigerant, metering device, driers, motor starting equipment, fan assembly or any other electrical component, etcetera.

The two year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to:
1. This system contains R404A or R134A refrigerant and polyol ester lubricant.  The polyol ester lubricant has rapid moisture absorbing qualities.  If long exposure to 
the ambient conditions occur, the lubricant must be removed and replaced with new.  For oil amounts and specifications please call TRUE technical service department  
(855-372-1368).  Failure to comply with recommended lubricant specification will void the compressor warranty.
2. Drier replacement is very important and must be changed when a system is opened for servicing.  A drier using XH-7 desiccant or an exact replacement solid core drier 
must be used.  The new drier must also be the same capacity as the drier being replaced.
3. Micron level vacuums must be achieved to insure low moisture levels in the system.  500 microns or lower must be obtained.

All claims for labor or parts must be made directly through TRUE.  All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of instal-
lation, and all pertinent information supporting the existence of the alleged defect.
 In case of warranty compressor, the compressor model tag must be returned to TRUE along with above listed information.
Any action or breach of these warranty provisions must be commenced within one (1) year after that cause of action has occurred.

TRUE’s sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below.  This warranty neither assumes nor authorizes any 
person to assume obligations other than those expressly covered by this warranty.
NO CONSEQUENTIAL DAMAGES.  TRUE IS NOT RESPONSIBLE FOR ECONOMIC LOSS; PROFIT LOSS; OR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, INCLUDING 
WITHOUT LIMITATION, LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE.
WARRANTY IS NOT TRANSFERABLE.  This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.  ANY SUCH ASSIGNMENT OR 
TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY 
OR FITNESS FOR A PARTICULAR PURPOSE.
IMPROPER USAGE.  TRUE ASSUMES NO LIABILITY FOR PARTS OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER DAMAGES RESULTING FROM IMPROPER 
USAGE OR INSTALLATION OR FAILURE TO CLEAN AND/OR MAINTAIN PRODUCT AS SET FORTH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT.
RELOCATION OF CABINET FOR REPAIR: True is not responsible for the cost to move a cabinet for any reason from its position of operation on the customer’s premises to make a 
warranty repair. 
RESIDENTIAL APPLICATIONS:  TRUE assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non-commercial or residential 
applications.
ALTERATION, NEGLECT, ABUSE, MISUSE, ACCIDENT, DAMAGE DURING TRANSIT OR INSTALLATION, FIRE, FLOOD, ACTS OF GOD.  TRUE is not responsible for the repair or 
replacement of any parts that TRUE determines have been subjected after the date of manufacture to alteration, neglect, abuse, misuse, accident, damage during transit or installation, fire, 
flood, or act of God.
IMPROPER ELECTRICAL CONNECTIONS.  TRUE IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM 
INCORRECT SUPPLY VOLTAGE, THE USE OF EXTENSION CORDS, LOW VOLTAGE, OR UNSTABLE SUPPLY VOLTAGE. 

NO IMPLIED WARRANTY OF MERCHANTABILITY 

OR FITNESS FOR A PARTICULAR PURPOSE:  THERE ARE NO OTHER WARRANTIES, EXPRESSED, IMPLIED OR STATUTORY, EXCEPT THE THREE (3) YEAR PARTS & LABOR 
WARRANTY AND THE ADDITIONAL TWO (2) YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE.  THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 
WARRANTIES, INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  THERE ARE NO WARRANTIES WHICH EXTEND 
BEYOND THE DESCRIPTION ON THE FACE HEREOF.
OUTSIDE U.S./Canada:  This warranty does not apply to, and TRUE is not responsible for, any warranty claims made on products sold or used outside the United States/Canada.  
This warranty only applies to units shipped from True’s manufacturing facilities after July 1, 2014.

WARRANTY INFORMATION (U.S.A & CANADA ONLY!)

T

RUE

 

R

EFRIGERATION

MADE IN

SINCE 1945

U.S.A.

®

Содержание T-19-HC

Страница 1: ...T 23 traditional reach ins TABLE OF CONTENTS SAFETY INFORMATION Safety Precautions 1 Proper Disposal Connecting Electricity Adapter Plugs 2 INSTALLATION Ownership Uncrating How to Connect to Electrici...

Страница 2: ...ty precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used CAUTION Risk of fire or explosion due t...

Страница 3: ...PROPERLY GROUNDED The power cord from this appliance is equipped with a grounding plug which minimizes the possibility of electric shock hazard Have the wall outlet and circuit checked by a qualified...

Страница 4: ...images 4 6 Do not throw the bracket or blocks away For future cabinet movement the bracket and blocks will need to be installed so the glass door does not receive any damage See image for bracket and...

Страница 5: ...10 14 14 14 14 14 14 14 12 12 12 10 10 12 14 14 14 14 14 14 12 12 12 10 10 10 14 14 14 14 14 14 12 12 12 10 10 10 8 16 14 14 14 14 12 12 12 10 10 10 8 8 18 14 14 14 12 12 12 10 10 10 8 8 8 20 14 14 1...

Страница 6: ...INSTALLATION OF CASTORS OR OPTIONAL LEGS Important Safeguard for installation of leg castor Images 1 5 demon strate procedure SECURING CASTORS AND LEGS To obtain maximum strength and stability of the...

Страница 7: ...floor on half inch inside the outline drawn The bead must be heavy enough to seal the entire cabinet surface when it is down on the sealant STEP 6 Raise and block the rear of the cabinet STEP 7 Apply...

Страница 8: ...to shelf standards B Position all four shelf clips equal in distance from the floor for flat shelves C Lower front of gravity feed TrueTrac organizers to enable proper feed D Place shelves on shelf cl...

Страница 9: ...shelf standard The shelf clip should not be loose or able to wiggle out of the shelf standard SHELF INSTALLATION TIPS 1 Install all the shelf clips before installing the shelves 2 Start at the bottom...

Страница 10: ...ng door Three Door Units Slide the middle door to the right so it is centered with the left edge of the right door See image 3 STEP 3 After centering the door lift it up and tilt top of door towards t...

Страница 11: ...fter cabinet is installed in a final location and correctly leveled check for any openings when the slide doors are completely closed If there are any gaps openings between the closed doors and cabine...

Страница 12: ...thin four inches of the evaporator housing Refrigerated air off the coil must circulate down the back wall NOTE If the unit is disconnected or shut off wait five minutes before starting again RECOMMEN...

Страница 13: ...ng unit base This timer is not used for a defrost event The timer will change the rotation of the reversing condenser fan motor MECHANICAL CONTROL FREEZER GENERAL SEQUENCE OF OPERATION 1 Cabinet is pl...

Страница 14: ...urn After making adjustment measure temperature during three cycles before adjusting again NOTE Only adjust the screw small flathead on the face of the control next to the cam See Figure 3 Follow the...

Страница 15: ...e as to which wire is on which spade terminal STEP 4 Pull out gently from cabinet NOTE Mechanical temperature controllers are affected when functioning at high altitude The cut in and cut out temperat...

Страница 16: ...ins www truemfg com O 9 8 7 6 5 4 3 2 1 2 O 9 8 7 5 4 3 2 1 CUT OUT CUT IN COLDER BUL NO CHART CCW Adjustment based on 360 complete turn Height 2000 42 3000 78 4000 114 5000 150 6000 186 7000 222 800...

Страница 17: ...LOCK OPERATION FOR UNITS WITH MECHANICAL CONTROL RECOMMENDED DEFROST SETTINGS TRUE Manufacturing has factory set your defrost time clock to a recommended time and duration defrost scenario All refrige...

Страница 18: ...temperature This cabinet temperature may reflect the refrigeration cycle of the Set Point and its Differential or it may show an average temperature The most accurate temperature on a cabinets operat...

Страница 19: ...g has been set correctly release the info button Wait 5 seconds for the display to show temperature See image 5 USING THE LAE ELECTRONIC CONTROL LOCKING AND UNLOCKING THE LAE CONTROLLER WHY Locking of...

Страница 20: ...prior steps and a temperature will appear ON Position TURNING THE GLASS DOOR MODEL LIGHTS ON AND OFF May need to unlock control WHY Light may be controlled by LAE Controller or interior light switch...

Страница 21: ...ure HOW TO CHANGE THE SET POINT STEP 1 To see the set point press and hold the Info button See image 1 STEP 2 While still holding the Info button press the Up or Down button to change the set point ST...

Страница 22: ...ME DEFROST TIM If controller is preprogrammed for TIM press and release the Manual Defrost button until dEF appears REAL TIME CLOCK RTC If controller is preprogrammed for RTC press the and hold the Ma...

Страница 23: ...E Depending on the version of control one of three parameters will appear ScL image 1a SPL image 1b MdL image 1c STEP 2 Push the Up button until dFt appears See image 2 STEP 3 Press and hold the Info...

Страница 24: ...HOW TO CHANGE DISPLAY READOUT FROM FAHRENHEIT TO CELSIUS STEP 1 To change the display press and hold the Info button and the Stand by button at the same time MdL or SPL will appear See images 1a and...

Страница 25: ...probe If probe T3 is not activated t3 will not appear of the display DISPLAYING TEMPERATURE PROBES T1 T2 T3 WHY To display temperature probe readings in different locations of the cabinet DISPLAY COD...

Страница 26: ...lsius AR2 28 SCL 1C ADO SPL X 32 1 8 AHM SPH X 32 1 8 AHT X 32 1 8 SP X 32 1 8 ACC C H IISM HYS X 1 8 IISL X 32 1 8 CRT IISH X 32 1 8 CT1 IISP X 32 1 8 CT2 IIHY X 1 8 CSD IIFC DFM HDS DFT IIDF DH1 SB...

Страница 27: ...ving the grill on these models Do not pinch wires For reinstall reattach the grill to the magnets on front of the cabinet and reinstall the screws on top of the grill Phillips Screwdriver Stiff Bristl...

Страница 28: ...ill to expose the Condenser The Condenser looks like a group of vertical fins You need to be able to see through the condenser for the unit to function at maximum capacity Do not place filter material...

Страница 29: ...RUST ON STAINLESS STEEL 1 USING THE CORRECT CLEANING TOOLS Use non abrasive tools when cleaning your stainless steel products The stainless steel s passive layer will not be harmed by soft cloths and...

Страница 30: ...e the plastic lampshield together and pull away from the door See Image 3 Push the bulb down while pulling the spring activated lampholder up This will give you enough clearance to take the bulb out S...

Страница 31: ...vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained All claims for labor or parts must be made directly throughTRUE All claims should include mo...

Отзывы: