4
TRUE
traditional
reach
-
ins
www
.
truemfg
.
com
T-72F WIRING CHANGES
(110V Application Only)
NOTE:
It is the customer’s responsibility to make sure receptacle
wiring meets all local electrical codes. TRUE recommends hiring a
licensed qualified electrician to make this change.
WIRING CONVERSION
At Receptacle Box:
1.
Turn breaker off
2.
Disconnect all wires from receptacle
3.
Insulate red wire (tape or wire nut)
4.
Connect black, white, and green
wires to 3 prong plug NEMA 5-20R per
instructions on receptacle.
At Breaker Panel:
1.
With breaker turned off, remove wires
2.
Remove double pole breaker
3.
Install single pole breaker
4.
Connect black wire to breaker
5.
Insulate red wire
6.
Turn breaker back on
Previous design: 4 prong plug NEMA 14-20R - 4 wire circuit (see
image 1). Current design: 3 prong plug NEMA 5-20R - 3 wire circuit
(see image 2).
1
2
230 Volts Distance In Feet To Center of Load
Amps 20 30 40 50 60 70 80 90 100 120 140 160
5
14 14 14 14 14 14 14 14 14 14 14 14
6
14 14 14 14 14 14 14 14 14 14 14 12
7
14 14 14 14 14 14 14 14 14 14 12 12
8
14 14 14 14 14 14 14 14 14 12 12 12
9
14 14 14 14 14 14 14 14 12 12 12 10
10
14 14 14 14 14 14 14 12 12 12 10 10
12
14 14 14 14 14 14 12 12 12 10 10 10
14
14 14 14 14 14 12 12 12 10 10 10 8
16
14 14 14 14 12 12 12 10 10 10 8 8
18
14 14 14 12 12 12 10 10 10 8 8 8
20
14 14 14 12 10 10 10 10 10 8 8 8
25
14 14 12 12 10 10 10 10 8 8 6 6
30
14 12 12 10 10 10 8 8 8 6 6 6
35
14 12 10 10 10 8 8 8 8 6 6 5
40
14 12 10 10 8 8 8 6 6 6 5 5
50
12 10 10 8 6 6 6 6 6 5 4 4
60 12
10 8 6 6 6 6 6 5 4 4 3
70 10
10 8 6 6 6 5 5 4 4 2 2
80 10 8 8 6 6 5 5 4 4 3 2 2
90 10 8 6 6 5 5 4 4 3 3 1 1
100 10 8 6 6 5 4 4 3 3 2 1 1
115 Volt s Distance In Feet To Center of Load
Amps 20 30 40 50 60 70 80 90 100 120 140 160
2
14 14 14 14 14 14 14 14 14 14 14 14
3
14 14 14 14 14 14 14 14 14 14 14 12
4
14 14 14 14 14 14 14 14 14 12 12 12
5
14 14 14 14 14 14 14 12 12 12 10 10
6
14 14 14 14 14 14 12 12 12 10 10 10
7
14 14 14 14 14 12 12 12 10 10 10 8
8
14 14 14 14 12 12 12 10 10 10 8 8
9
14 14 14 12 12 12 10 10 10 8 8 8
10
14 14 14 12 12 10 10 10 10 8 8 8
12
14 14 12 12 10 10 10 8 8 8 8 6
14
14 14 12 10 10 10 8 8 8 6 6 6
16
14 12 12 10 10 8 8 8 8 6 6 6
18
14 12 10 10 8 8 8 8 8 8 8 5
20
14 12 10 10 8 8 8 6 6 6 5 5
25
12 10 10 8 8 6 6 6 6 5 4 4
30 12
10 8 8 6 6 6 6 5 4 4 3
35 10
10 8 6 6 6 5 5 4 4 3 2
40 10 8 8 6 6 5 5 4 4 3 2 2
45 10 8 6 6 6 5 4 4 3 3 2 1
50 10 8 6 6 5 4 4 3 3 2 1 1
WIRE GAUGE CHART