TEC_TM_065 REV. B
03/31/2022
Page 8 of 48
TRUE RESIDENTIAL
®
P R I O R T O I N S T A L L A T I O N
• Rough Opening dimensions. (See figure 1 and 2)
• For FLUSH installations the front face of the unit will be flush with the surrounding cabinets. (See figure 3)
• For PROUD (Standard) installations, the front face of the unit will extend beyond cabinets. (See figure 4)
NOTE: IT IS NOT RECOMMENDED TO INSTALL UNITS SIDE BY SIDE WITH HINGES TOUCHING
E ACH OTHER. IF YOU PL AN TO INSTALL UNITS HINGE TO HINGE, CALL TECH SUPPORT AT
8 4 4 -74 6-9 423 FOR INSTALL ATION INSTRUCTIONS.
TR-42
TR-48
FLUSH
PROUD
FLUSH
PROUD
WIDTH
42
1/4
”
41
3/4
”
48
1/4
”
47
3/4
”
DEPTH
26”
24”
26”
24”
HEIGHT
84
1/4
”
84”
84
1/4
”
84”
WEIGHT*
720 Lbs
720 Lbs
820 Lbs
820 Lbs
Cord Length
8 feet
8 feet
8 feet
8 feet
* Because of the weight of this unit, it is recommended to consult a flooring exper t prior to inst allation. The flooring beneath the unit
should be rated to suppor t at least 150 pounds per square foot.
41
3/4
" PROUD INSTALL
42
1/4
" FLUSH INSTALL
8"
Electrical located in
this area
2"
84
1/4
"
FLUSH
INSTALL
84"
PROUD
INSTALL
77"
26" MINIMUM
FLUSH INSTALL
24" MINIMUM
PROUD INSTALL
SITE PREPAR ATION
ME ASUREMENTS & WEIGHT
TR-42
TOP VIEW
FIGURE 1 – ROUGH OPENING
FLUSH INSTALL
FRONT VIEW
FIGURE 2 – ROUGH OPENING
TOP VIEW
FIGURE 1 – ROUGH OPENING
PROUD INSTALL
Dimensions may var y by ± 1/8 " (3.2 mm)