FIG. 11.
Remove and discard the interior magnet brackets.
FIG. 12.
Magnet bracket screw locations.
JOINING KIT INS TALL ATION (CONT.)
Kit Sizes: 60" (1524 mm) / 72" (1828.8 mm) / 78" (1981.2 mm) / 90" (2286 mm)
7. Install anti-sweat foam end panels on the joined
units’ sides where the cabinets will meet. See figs.
13 and 14.
8. Position the units in front of the final installation
location. Then, level the units.
9. Verify the fronts of the units are flush at the seams
and the gap(s) between the units is (are) consistent
from top to bottom. See figs. 15 and 16.
10. With the provided hardware, install the joining
bracket across the interior legs. See figs. 17 and
18.
11. With the existing hardware, install the joining
rainshield assembly. See fig. 19.
NOTE: ASSISTANCE (AT LE AST T WO (2)
PEOPLE) RECOMMENDED.
12. Route the reed switch wires through the rainshield.
See figs. 6 and 7.
13. With the predrilled holes in the joining rainshield,
connect and install the reed switches near the
handle-side of the units.
NOTE: BE SURE TO CONNECT THE
WIRES TO THE REED SWITCH AS
ORIGINALLY CONFIGURED. WIRE
LOCATION IS CRITICAL TO THE
CABINET ’S OPER ATION. SEE
FIGS. 5 OR 20.
FIG. 13.
Install the anti-sweat foam panel where the unit will be
positioned next to another unit.
FIG. 14.
Install foam pads between the joined units.
Application Area Two Pads Used