TEC_TM_065 REV. B
03/31/2022
Page 12 of 48
TRUE RESIDENTIAL
®
P R I O R T O I N S T A L L A T I O N
41
3/4
" PROUD INSTALL
42
1/4
" FLUSH INSTALL
8"
Electrical located
in this area
2"
84
1/4
"
FLUSH
INSTALL
84"
PROUD
INSTALL
77"
ELEC TRICAL REQUIREMENTS
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration
(See Figure 5). Follow the National Electrical Code
and local codes and ordinances when installing
the receptacle. A dedicated circuit, supplying only
this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
• Power Supply 115 V AC, 60 Hz
• Circuit Breaker 15 amp
• Receptacle 3-prong grounding-type
NOTE: THE OUTLET MUST BE CHECK ED BY A
QUALIFIED ELECTRICIAN TO BE SURE THAT
IT IS WIRED WITH THE CORRECT POL ARIT Y.
VERIF Y THAT THE OUTLET IS PROPERLY
GROUNDED.
FIGURE 5
FRONT VIEW ROUGH OPENING
& ELECTRICAL ARE A