TEC_TM_065 REV. B
03/31/2022
Page 29 of 48
TRUE 42 /4 8 INSTALL MANUAL
I N S T A L L A T I O N
FIG. 17.
Return the magnet bracket screws to their original locations
FIG. 15.
Verify the cabinet fronts are flush. Adjust the units
accordingly.
FIG. 16.
Verify the gap(s) between cabinets is (are) even throughout.
FIG. 18.
Installed joining bracket.
FIG. 19.
Installed joining rainshield.
FIG. 20.
Connect the reed switches with the original wire configurations.
14. Walk the joined units into their final installation
location.
15. Verify the level of the cabinets. Level the units as
needed.
16. Restore power to the units and turn the units on.
17. After 3 minutes of runtime, open the doors
individually and verify correct door switch
operation. When operating correctly, the following
should occur:
• Unless set otherwise, the lights turn on and off with
the door openings.
• The evaporator (interior) fan turns on and off with
door openings.
• There is a low-pitched click from the control board
area when the door opens or shuts.
18. Install the joining kit grill.
JOINING KIT INS TALL ATION (CONT.)
Kit Sizes: 60" (1524 mm) / 72" (1828.8 mm) / 78" (1981.2 mm) / 90" (2286 mm)
1
2
3