ADA HEIGHT INSTALL GUIDE
TEC_TM_120 REV. B
02/02/2022
Page 37 of 74
I N S T A L L A T I O N
LE VELING
Proper leveling of your TRUE unit is critical to
operating success. Leveling impacts effective
condensate removal and door operation.
With the cabinet in the final installation location, level
the unit front-to-back and side-to-side.
PROCEDURE
1. Position the level on the inside floor of the unit
near the doors (the level should be parallel to
cabinet front). Level the cabinet.
2. Position the level at the inside rear of the cabinet
(again, the level should be placed parallel to
cabinet back). Level the cabinet.
3. Perform procedures similar to steps 1 and 2 by
placing the level on the inside floor (left and right
side, parallel to the depth of the cooler). Level the
cabinet.
KICKPL ATE INS TALL ATION
PROCEDURE
1. Locate the kickplate secured to the back of the
unit.
2. Position the kick plate below the door. See fig. 1.
3. Verify the kickplate correctly aligned. Adjust as
needed.
FIG. 1.
Attach the kickplate to the magnets below the door.