background image

CHAPTER 1: SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 

SAVE THESE SAFETY INSTRUCTIONS 

This lateral trainer is intended for a commercial or institutional setting.  This owner’s manual should be accessible to all personal 

trainers, staff members, and members.   

WARNING: All EXERCISERS MUST READ ALL INSTRUCTIONS BEFORE USING THE LATERAL TRAINER. 
WARNING: Heart rate monitoring systems may be inaccurate. Over exercise may result in serious injury or 

death. If you feel faint stop exercising immediately.
WARNING: Equipment should be immediately taken out of use if it fails to work properly or when a warning is 

presented electronically.

 

TRUE STRONGLY recommends seeing a physician for a complete medical exam before undertaking an exercise program, 

particularly if the user has a family history of high blood pressure or heart disease, is over the age of 45, smokes, has high 

cholesterol, is obese or has not exercised regularly in the past year.  Additionally, TRUE recommends consulting a fitness 

professional on the correct use of this product. If at any time while exercising the user experiences faintness, dizziness, pain or 

shortness of breath, he or she must stop immediately.       

WARNING: To reduce the risk of electrical shock, always unplug this TRUE product before cleaning or attempting any 

maintenance activity.  Do not handle the plug with wet hands. 
WARNING: To reduce the risk of burns, fire, electric shock or injury, it is imperative to connect each product to a 

properly grounded 110V electrical outlet. A risk of electrical shock may result from improper connection of the 

equipment’s grounding conductor. Check with a qualified electrician if you are unsure about proper grounding 

techniques. Do not modify the plug provided with this product. If it will not fit an electrical outlet, have a proper outlet 

installed by a qualified electrician. Your TRUE Fitness product must be properly grounded to reduce risk of shock if the 

lateral trainer malfunctions. Your lateral trainer may be equipped with an electrical cord, which includes an equipment 

grounding conductor and a grounding plug. The plug must be inserted into an outlet that has been properly installed 

and grounded in accordance with all local codes and ordinances. A temporary adapter cannot be used to connect this 

plug to a two-pole receptacle in North America. If a properly grounded 15 amp outlet is not available, a qualified 

electrician must install one. 
WARNING: Do not move the equipment by lifting the console. Do not use the console as a handlebar during a workout. 
WARNING: This product contains chemicals known to the state of California to cause cancer and birth defects or other 

reproductive harm. 
WARNING: Keep equipment stable on flat ground. 
WARNING: Replace warning labels that may be worn, damaged or missing. 
WARNING: Replace any non-working or damaged components; remove the unit from service until repair is performed. 
WARNING: To reduce the risk of burns, fire and electric shock or injury to persons, follow these instructions: 

This appliance should never be left unattended when plugged in.

Do not use any type of extension cord with this product.

Unplug it from the outlet when not in use and before any servicing.

Do not operate the equipment while being covered with a blanket, plastic, or anything that insulates or stops

airflow.

Truefitness.com / 800.426.6570 / 636.272.7100 

Содержание fuse XL-1000

Страница 1: ...Assembly Guide Warranty Card Included Revision 091418 TRAVERSE LATERAL TRAINER OWNER S MANUAL Model XL1000...

Страница 2: ...taire s il vous pla t visitez www truefitness com Pour documents dans des langues suppl mentaires veuillez www truefitness com resources document library de visite www truefitness com www truefitness...

Страница 3: ...e full product line has made TRUE successful and is a trademark of the TRUE heritage TRUE s patented Heart Rate Control technology is just one of the remarkable ways we deliver simple and superior per...

Страница 4: ...al Assembly Steps Wiring Diagrams Exploded Views Chapter 3 Product Overview 23 Traverse Overview Chapter 4 Care Maintenance 25 25 26 26 27 27 28 Care Maintenance Cleaning the Equipment Other Scheduled...

Страница 5: ...om improper connection of the equipment s grounding conductor Check with a qualified electrician if you are unsure about proper grounding techniques Do not modify the plug provided with this product I...

Страница 6: ...om heated surfaces Do not pull the equipment by the power cord or use the cord as a handle Do not run the power cord along the side or under the lateral trainer If the electrical supply cord is damage...

Страница 7: ...the possibility of bystanders being struck or caught between moving parts by making sure that they are out of reach of the lateral trainer while it is in motion Allow only one person at a time on the...

Страница 8: ...he outlet have a proper outlet installed by a qualified electrician Do not remove the motor cover or you may risk injury due to electric shock The 120 V model is for use on a nominal 120 V circuit and...

Страница 9: ...CHAPTER 1 SAFETY INSTRUCTIONS Truefitness com 800 426 6570 636 272 7100 5...

Страница 10: ...00 883 8783 COMPLIANCES This equipment complies with all applicable codes and regulations For a complete list of compliances please visit www truefitness com PROPER TRAINING POSITION Users should keep...

Страница 11: ...for incorrect worn or loose components and do not use until corrected replaced or tightened prior to use Do not wear loose or dangling clothing while using the lateral trainer Care should be used whe...

Страница 12: ...UCS0024BK IPOD TRAY PAD BLACK 1 11 TL1014BK DOME COVER WITH DECAL 1 12 TL1015BK DOME COVER GASKET 1 13 TL10MF020X TRANSPORT WHEEL BRACKET ASSEMBLY 1 14 TL1057 SHCS M8 1 25 x 20 Black 14 15 TL0045 PPHM...

Страница 13: ...ed in pedals Spring Washer Qty 4 Step 5 Install Upright Step 7 Install Handlebar M8x20mm Allen Bolt Qty 4 M8x20mm Allen Bolt Qty 3 Step 8 Install Transport Plate Step 9 Install Storage Tray M8x20mm Al...

Страница 14: ...INSTRUCTED TO IN STEP 7 b Cut the 4 corners of the base cardboard and lay the sides flat STEP 2 ASSEMBLE THE LEFT AND RIGHT STABILIZER BARS a Attach the end caps B to both the Left and Right Stabiliz...

Страница 15: ...al Assembly and remove the pedal from the pedal mount NOTE 3 bolts are in the pedal assembly and the 4th bolt is in the hardware pack for each pedal b Align the bolt holes on the pedal mount C with th...

Страница 16: ...ws to separate the Console Mount from the Upright Post NOTE Retain the screws for use in step 6 b Set the Upright Post on the machine base and line up the holes as shown Install 4 bolts to secure the...

Страница 17: ...r Gasket over the top of the Upright and pull the wires through the opening Slide this Rubber Dome Cover down until it fits firmly into the Plastic Dome Cover NOTE The Rubber Dome Cover is not symmetr...

Страница 18: ...nued STEP 6 ASSEMBLE CONSOLE MOUNT AND CONNECT WIRES a Route the cables through the hole in the Console Mount as shown and place the console mount on top of the Upright Use caution to not pinch the wi...

Страница 19: ...shown e Connect the contact heart rate cables as shown f f Secure the contact heart rate cables to the upright assembly using the two zip ties CHAPTER 2 ASSEMBLY INSTRUCTIONS Truefitness com 800 426 6...

Страница 20: ...Tilt machine forward so that it rests on the ground in these 2 locations b Install the Transport Plate N with the 4 bolts as shown and firmly tighten c Using 2 people stand the machine back up STEP 1...

Страница 21: ...he Power Supply to the DC Power Cable g Disconnect the DC Power Cable from the Lower Electronics Board Cable in the area circled Once disconnected reconnect the DC Power Cable to the AUXPS DC Power Ca...

Страница 22: ...t pinch any wires c Use 5 screws to tighten the Rear Console Cover to the back of the console STEP 13 MOVE MACHINE TO FINAL LOCATION AND SET LEVELING FEET a Tilt the machine forward by holding onto th...

Страница 23: ...efitness com 800 426 6570 636 272 7100 19 WIRING DIAGRAMS Heart Rate Right Heart Rate Left Combo Heart Rate Board Power In Power Out USB XL1000 C Safe Console Fan 7XL0010 7XL0010 7XL0002 7XL0003 7XL00...

Страница 24: ...TER 2 ASSEMBLY INSTRUCTIONS 20 WIRING DIAGRAMS continued Heart Rate Right Heart Rate Left Combo Heart Rate Board Power Out Self Generating Power XL1000 USB C Safe Console Fan 7XL0010 7XL0010 7XL0002 7...

Страница 25: ...0 FE0090 TL1003 TL1014BK TL0039 TL0039 TL0039 TL0039 UCS0032BK TOP CAP 00619300 TL1019 TL1037BK TL1034 D 00588800 00591500 00595500 TL1001 TL1002 TL1008 TL0015 TL1017A TL1017A TL1013BK TL1013BK TL1016...

Страница 26: ...IRE ROUTING SIDE VIEW WIRE ROUTING BOTTOM VIEW WIRE ROUTING BACK VIEW BATTERY FUSE ADDED TO THIS WIRE ROUTING Truefitness com 800 426 6570 636 272 7100 22 CHAPTER 2 ASSEMBLY INSTRUCTIONS EXPLODED VIEW...

Страница 27: ...tness com 800 426 6570 636 272 7100 23 CHAPTER 3 PRODUCT OVERVIEW TRAVERSE OVERVIEW Leveling Feet Battery Charge Port Foot Pads Console Assembly Contact Heart Rate Pads Coaxial Port Ethernet Port Powe...

Страница 28: ...strap Foot Pads Moving pedals on the unit that provide resistance to the lower body during a workout Leveling Feet An adjustable system used to aid in the leveling the unit Coaxial Port Delivers tele...

Страница 29: ...cord from its power source Make sure other users know that the lateral trainer needs service To order parts or to contact a TRUE Authorized Service representative please visit www truefitness com CLE...

Страница 30: ...or abnormal or premature wear CAUTION Use only TRUE Fitness certified service providers LONG TERM STORAGE When the lateral trainer is not in use for any length of time turn it off Make sure that the p...

Страница 31: ...ay also contact TRUE Fitness customer support team by calling 800 883 8783 or e mailing us at service truefitness com Monday Friday during normal business hours TRUE FITNESS SERVICE DEPARTMENT 865 HOF...

Страница 32: ...not You must sign the bill of lading as damaged when accepting the shipment Once you have opened the box and you have determined something is indeed damaged please gather the serial number model numb...

Страница 33: ...Power cord not fully seated in socket Inspect power connection at the unit and outlet Insufficient power Verify output voltage from 20A outlet with a voltmeter Error code is displayed on console Cont...

Страница 34: ...e space in between units Environmental interference from high voltage power lines Move the unit to another position within the room or move the cause of the interference until heart rate reading are s...

Страница 35: ...connected Console configured incorrectly Power cycle Re configure console Loose cable Check cable connections Fault CN07 Calibration Timeout Console Incline Calibration was not able to complete within...

Страница 36: ...and warnings in owner s manual accident misuse abuse unauthorized modification or failure to provide reasonable and necessary maintenance TRUE Fitness shall not warrant the performance of the heart ra...

Страница 37: ...not include labor beyond the above warranty period transportation service return and freight charges associated therewith except as expressly specified herein 7 This Limited Warranty shall not apply...

Страница 38: ...ree Weights Gym Brand ________________ 5 How many people use your facility on a daily basis ___ a 25 ___ b 25 75 ___ c 76 150 ___ d 150 6 Do you plan to purchase more fitness equipment in the next 6 1...

Отзывы: