background image

2001 East Terra Lane • O'Fallon, MO. 63366 • ph. 636.240.2400 • toll free 800. 325.6152 • [email protected] 

GDM SERIES COOLER EQUIPPED WITH EMS (ELSTAT) CONTROL

FREQUENTLY ASKED QUESTIONS

HOW?

•  Push the set button key (looks like a snow flake) the screen should show PAS

•  You will now need to enter the key dance

•  Press the snow flake key 3 beeps

•  Press the up arrow key 2 beeps

•  Press the down arrow key1 beep

•  Press the water drops key4 beeps (should show display of "PS")

•  Press and hold the down arrow key until you view HR

•  Press the snow flake key (display should show PAS)

•  Re enter key dance and the Half Reset is complete.

How do I perform a Half reset, and what is it?

  

Half reset clears any of the learning memory.

WHAT?

 

How do I put controller into Perishable mode? 

•  Perishable mode is used when anything perishable is being stored in the cabinet.
•  In perishable mode, cabinet will maintain a 36°F-38°F product temperature. The 

cabinet will not go into standby mode.

HOW?

•  Press the set button key (looks like a snow flake): the screen should show PAS

•  You will now need to enter the key dance: 

•  Press the snow flake key 3 beeps

•  Press the up arrow key 2 beeps

•  Press the down arrow key1 beep

•  Press the water drops key 4 beeps (should show display of "PS")

•  Now press and hold down the snow flake key until the screen shows PEr and 00.

•  Next press and hold the up arrow key until the screen shows PEr and 01.

•  Wait until controller reads "USE"; unplug the cabinet and plug it back in. At this  

  point the red LED in center of the control should be “on” which means that the  

  control is in perishable mode. 

Can the Elstat come out of the "Stand by" mode before its predetermined time?

No.

 If the motion sensor is set off during the "Stand by" mode the control will automatically 

turn the lights on, however it will stay in stand by mode.

Can the Elstat be set up for continuous use and  not go into the "Stand by" mode?

Yes.

 The control can be set into perishable mode. This would shut down the "stand by" 

mode. The lights will still cycle (like stand by mode) when cabinet doesn't see activity.

NOTE: There is no ability to set lights on all the time.

Can lights be set to stay on at all times?

No.

 Elstat controller does not have this capability. Lights will always turn off in "stand by" 

Mode.

NOTE: All Energy Star cabinets are shipped in perishable mode

   7

Содержание GDM-26

Страница 1: ...ELSTAT TRAINING BOOKLET GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL GDM 26...

Страница 2: ...CONTENTS ELSTAT SEQUENCE OF OPERATION ELSTAT COMPONENTS FRONT VIEW OF ELSTAT REAR VIEW OF CONTROLLER FREQUENTLY ASKED QUESTIONS FAQ NORMAL OPERATING CODES FAULT CODES TROUBLESHOOTING TROUBLESHOOTING...

Страница 3: ...me the controller is on it is learning the customer traffic Once enough data has been accumulated the controller will now cycle between two modes Standby and Use In the standby mode the controller pre...

Страница 4: ...porator fan motor Probe Location 1 GDM 45 to GDM 72 Probe is in the discharge air stream Off of the Evaporator Coil GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL ELSTAT COMPONENTS Probe Transform...

Страница 5: ...ra Lane O Fallon MO 63366 ph 636 240 2400 toll free 800 325 6152 service truemfg com GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL FRONTVIEW OF ELSTAT Waterdrops Snowflake Up Down Key Perishable...

Страница 6: ...2400 toll free 800 325 6152 service truemfg com NO NAME 1 Line In 2 Lights 3 Not Used 4 Appliance Sensor 5 Compressor 6 Fan s 7 12 Vac 8 Not Used 9 Not Used GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT...

Страница 7: ...o enter the key dance Press the snow flake key 3 beeps Press the up arrow key 2 beeps Press the down arrow key1 beep Press the water drops key 4 beeps should show display of PS Now press and hold down...

Страница 8: ...Probe Ohm out evaporator probe Faulty Controller Bypass control to see if system will run Parameters have been changed Check the parameter list Power supply voltage is low Possible Problems Action to...

Страница 9: ...de 2 Move cabinet or put into Perishable mode 3 Unit was in a previous location 3 Perform half reset Warm Product 1 Unit in a unpredictable location Elstat control may be going into standby mode 1 Mov...

Страница 10: ...JY 2 2013 2001 East Terra Lane O Fallon MO 63366 ph 636 240 2400 toll free 800 325 6152 service truemfg com...