GDM SERIES COOLER EQUIPPED WITH EMS (ELSTAT) CONTROL

NORMAL OPERATING CODES

Normal operating mode. Cabinet 

should be holding proper product 

temperature.

Units is in Standby mode. Control 

will cycle the unit at a warmer 

temperature. Lights will be off.

Units is in defrost . Compressor has 

been shut off and evaporator fan 

motor is running to clear any ice 

that may have accumulated. This is a 

predetermined program function.

Freeze up protection. This unit has 

gone down below the minimum 

temperature Set Point.

Possible Problems

Action to take

Compressor not shutting off

Check compressor. Relay at 

controller

Faulty Probe

Ohm out evaporator probe

Parameters have been 

changed

Check parameter list

Refrigeration System Failure. The unit 

has not satisfied the set point in the 

amount of time allowed.

Possible Problems

Action to take

Unit is not cooling 

Check the Refrigeration System

Faulty Probe

Ohm out evaporator probe

Faulty Controller

Bypass control to see if system will 

run

Parameters have been 

changed

Check the parameter list

Power supply voltage is low.

Possible Problems

Action to take

Poor voltage at outlet

Verify proper voltage to cabinet

Faulty Transformer

Verify 120V to transformer. Check for 

12V on secondary. Connector 7 

(see page 2)

Faulty Controller

Bypass control to see if system will run

Faulty Elstat

If 12V is present at connector 7, replace 

Elstat

Power supply voltage is too high.

Possible Problems

Action to take

High voltage at outlet

Verify proper voltage to cabinet

Faulty Transformer

Verify 120V to transformer. Check for 

12V on secondary. Connector 7 

(see page 2)

Faulty Elstat

If 12V is present at connector 7, replace 

Elstat.

Probe failure

Possible Problems

Action to take

Connector off at controller Verify that connector 4 is in place 

(see page 2)

Probe is open

Ohm out probe

Probe is shorted

Ohm out probe

Probe wire is open

Ohm out probe wire

Elstat Probes by the evaporator motor GDM-10 to 33 probes in air 

stream GDM-35 to 72

Value

Ohms

32°

32,000 Ohms

70°

12,000 Ohms

80°

9,300 Ohms

85°

8,500 Ohms

90°

7,000 Ohms

FAULT CODES/ TROUBLESHOOTING

8   

Содержание GDM-26

Страница 1: ...ELSTAT TRAINING BOOKLET GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL GDM 26...

Страница 2: ...CONTENTS ELSTAT SEQUENCE OF OPERATION ELSTAT COMPONENTS FRONT VIEW OF ELSTAT REAR VIEW OF CONTROLLER FREQUENTLY ASKED QUESTIONS FAQ NORMAL OPERATING CODES FAULT CODES TROUBLESHOOTING TROUBLESHOOTING...

Страница 3: ...me the controller is on it is learning the customer traffic Once enough data has been accumulated the controller will now cycle between two modes Standby and Use In the standby mode the controller pre...

Страница 4: ...porator fan motor Probe Location 1 GDM 45 to GDM 72 Probe is in the discharge air stream Off of the Evaporator Coil GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL ELSTAT COMPONENTS Probe Transform...

Страница 5: ...ra Lane O Fallon MO 63366 ph 636 240 2400 toll free 800 325 6152 service truemfg com GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT CONTROL FRONTVIEW OF ELSTAT Waterdrops Snowflake Up Down Key Perishable...

Страница 6: ...2400 toll free 800 325 6152 service truemfg com NO NAME 1 Line In 2 Lights 3 Not Used 4 Appliance Sensor 5 Compressor 6 Fan s 7 12 Vac 8 Not Used 9 Not Used GDM SERIES COOLER EQUIPPED WITH EMS ELSTAT...

Страница 7: ...o enter the key dance Press the snow flake key 3 beeps Press the up arrow key 2 beeps Press the down arrow key1 beep Press the water drops key 4 beeps should show display of PS Now press and hold down...

Страница 8: ...Probe Ohm out evaporator probe Faulty Controller Bypass control to see if system will run Parameters have been changed Check the parameter list Power supply voltage is low Possible Problems Action to...

Страница 9: ...de 2 Move cabinet or put into Perishable mode 3 Unit was in a previous location 3 Perform half reset Warm Product 1 Unit in a unpredictable location Elstat control may be going into standby mode 1 Mov...

Страница 10: ...JY 2 2013 2001 East Terra Lane O Fallon MO 63366 ph 636 240 2400 toll free 800 325 6152 service truemfg com...

Отзывы: