2.2 Connecting the Water Supply and Waste to the K9000 2.0.
Before connecting the K9000 2.0 to water and waste ensure local regulations are
considered. Some sites may require an additional back flow prevention device. Local
regulations may also require sites to use copper pipes for waste.
2.2.1
Connecting the Water Supply
Flush the pipes prior to connecting to the K9000 2.0. Maximum allowable water pressure is
0.5Mpa. (72 psi / 500Kpa).
The picture at left shows the hot and cold-water entry points for a K9000 2.0 without an on-
board hot water unit. While the picture on the right shows the water entry point for a K9000
2.0 with an on-board hot water unit.
Once connected the regulator can be adjusted to ensure the K9000 2.0 has water pressure
of between 20 & 30 psi when the pressure gun is in use and between 40 & 50 psi when
pressure gun is not being utilised.
To verify the pressure when the gun is not being utilized you need to view the gauge at the
moment the pressure gun is turned off
as it will give a true indication of the psi prior to
resetting to the hold psi of approximately 40psi.
•
The psi verification can be done with the override key and a wash setting of stop or
with money/token and the rinse setting selected.
If adjustment required, you will need to adjust the regulator. The regulator is adjusted using
a screw driver, where pressure needs to be increased turn the screw anticlockwise and to
decrease pressure turn in a clockwise direction.
Cold water
connection
Cold water
connection
Hot water system
on board
Hot water
connection
Site Supplied
Hot Water