https://k9000dogwash.sharepoint.com/sites/K9000/Shared Documents/General/Build/Furever Clean/Furever Clean K9000
2.0/K9000 2.0 Canadian Operators Manual v2.0.docx
Page 25
Last edited 02/04/2019
© Atlantic Industries 2018
4.1.2.1 Bleeding Product Dosing Pumps (Iwaki - EJ Series Pumps)
The need to bleed product dosing pump will arise when products have run out or in some
case when products have been replaced and air has become trapped in the tube.
Bleeding procedure:
1. Select the product you wish to bleed by pushing the number associated with the
product on the key pad e.g. 1 for shampoo, 2 for rinse etc
2.
Release bleeder valve (item A below) by turning anti-clockwise as shown below;
3
turns maximum.
3. Once product reaches the clear waste tube (item B below) re-tighten the bleeder
valve by turning clock-wise;
4. After process is complete visually inspect the suction line for air pockets, if air pockets
are present repeat the process.
NOTE: After pump has been bled, there will be a distinctive change in the sound of the pump
(pump will sound quieter).
If there are problems bleeding heavier concentrates rattle the suction line (item C
below), and/or squeeze it to assist with shifting the product up into the pump head.
A
B
C
Содержание K9000 2.0