TractionAir
7
2.
Fit the pressure protection valve TAPR2-90 hard-piped to the auxiliary
air tank. The PR2 Valve protects the integrity of the vehicle’s Air Brake
System (ABS) and must be installed vertically.
Mount with the white Plastic Knob facing up
Plumb INLET
= Side Port (DEL)
OUTLET = End Port (SUP)
AIR IN
AIR OUT
Wheel End Mounting
Depending on the make of the vehicle, position both inner and outer wheels so
that the valve stems are opposite each other (180 degrees apart).
This may require rotating both inner and outer wheels. The easiest way of
achieving this, is to position the Wheel Bridge so that the hose nipple points
straight at the inner valve stem.
Remove any studs that will allow for this alignment. The inner hose will now
point straight at the valve stem. This method means that only the outside wheel
will need rotating to line up with the corresponding hose nipple. The two wheels
should now have their valve stems opposite each other, which is critical to a
successful job.
Содержание TractionAir
Страница 27: ...TractionAir 27...