4–8
Press the
〈
ENTER/START
〉
key. The gauge displays:
Averaging Mode
Reading #: 1
Press <START>
<STORE>/<ESC> to End
Place the gauge on the first test site and press
〈
ENTER/START
〉
.
The gauge takes a measurement, then displays the results:
##.#% Gmb(MA)
##.#% Gmm(Voidless)
Avg of 1: ###.#
#.#% Voids <ENTER>
NOTE
If the Temperature option (see page 2–10) is installed, the
mat temperature is also shown in the upper right corner
of the display.
Press
〈
ENTER/START
〉
to continue. Repeat the steps above to take
a measurement at up to 30 test locations. When all locations are
complete, press the
〈
STORE
〉
or
〈
ESC
〉
key to continue.
If the
〈
ESC
〉
key is pressed, the gauge displays:
End of Measurement
Do You Want To
Store ?
<YES> or <NO>
Press
〈
NO
〉
to return to the
Ready
screen without storing the results
or
〈
YES
〉
to continue as described below.