dehumidifier TTK 900 MP

Storage

Before

 storing the device, proceed as follows:

Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Drain any possibly remaining condensate.

When the device is not being used, observe the following
storage conditions:

Only store the device in a room measuring more than 4 m

2

.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

dry and protected from frost and heat

in an upright position where it is protected from dust and
direct sunlight

with a cover to protect it from invasive dust, if necessary

Place no further devices or objects on top of the device to
prevent it from being damaged.

Assembly and start-up

Scope of delivery

1 x Device

1 x Air filter

1 x Condensation drain hose, 14 mm diameter

1 x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.

A

B

C

C

D

Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.

Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

Only put up the device in an upright, stable position on firm
ground.

Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

Make sure that extension cables are completely unrolled.

When positioning the device, keep a sufficient distance to
heat sources.

Make sure that no curtains or other objects interfere with
the air flow.

When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.

Содержание TTK 900 MP

Страница 1: ...TRT BA TTK900MP TC2021 11 001 EN TTK 900 MP EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...nk TTK 900 MP https hub trotec com id 44937 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use War...

Страница 3: ...afety warnings for devices containing flammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is...

Страница 4: ...e Any use other than the intended use is regarded as a reasonably foreseeable misuse Personnel qualifications People who use this device must be aware of the dangers that occur when working with elect...

Страница 5: ...nect a defective device to the mains Information about the device Device description The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through...

Страница 6: ...the maximum number of components to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a transport handle and tw...

Страница 7: ...the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe the minimum dista...

Страница 8: ...sen the screw 14 2 Remove the screw 13 13 14 15 3 Turn the transport handle by 90 13 14 4 Insert the screw 13 in the rivet 15 5 Tighten the screws 14 15 Inserting the air filter Note Do not operate th...

Страница 9: ...in hose as follows Place a sufficiently dimensioned container at least 90 litres beside the device and insert the hose end Check the filling level of the container regularly Position the end of the co...

Страница 10: ...10 EN dehumidifier TTK 900 MP 3 4 5 6 7 8...

Страница 11: ...19 The device is switched on The compressor always starts with a delay of approx 7 s The fan starts approx 10 s after that Continuous operation mode In continuous operation mode the device dehumidifie...

Страница 12: ...lower value The device is running but there is no formation of condensate Check whether the condensation drain hose is positioned correctly When using the condensate pump Check the condensation tank...

Страница 13: ...crews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty the condensate pump condensation tank and constructio...

Страница 14: ...safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Make sure that no moistu...

Страница 15: ...aused by ejected compressed air upon activation of the compressed air supply Hold the compressed air hose away from your body Pointing the compressed air hose at another person is prohibited Note If r...

Страница 16: ...ice to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter Technical annex Technical data Parameter Value Model TTK...

Страница 17: ...EN 17 dehumidifier TTK 900 MP Wiring diagram TTK 900 MP With operating hours counter...

Страница 18: ...tions of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY H1 Top panel 1 H8 Tubular handle screw 4 H2 Right panel 1 H9 Saddle spacer 4 H3 Left panel 1 H10...

Страница 19: ...of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY B1 Base plate 1 B8 Tubular foot 1 B2 Compressor 1 B9 Saddle foot 2 B3 Running capacitor 1 B10 Round in...

Страница 20: ...g the positions of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY C1 Sealed electronic controller 1 C6 Defrost valve coil 2 C2 Body sheet metal 1 C7 Fan...

Страница 21: ...entioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY D1 Control s box 1 D7 Remote humidistat socket 1 D2 Control s cover 1 D8 Control s box internal wiring 1 D3 Electronic co...

Страница 22: ...se of the refrigerant appropriately and according to the national regulations Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part...

Страница 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: