EN
dehumidifier TTK 900 MP
3. Loosen and remove the screws at the rear of the device.
4. Keep the screws safe for later use.
5. Fully unwind the power cable. If required, remove the
condensation drain hose from the device.
6. Lift the housing off the base frame and the cooling system
by the transport handle.
7. Carefully set the housing aside.
8. Clean the interior of the device by means of compressed
air.
9. Reassemble the housing on base frame and cooling
system. Finally retighten all screws.
Activities required after maintenance
If you want to continue using the device:
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Model
TTK 900 MP
Art. no.
1.120.000.802
Max. dehumidification
performance
110 l / 24 h
Air flow rate
Stage 1
Stage 2
600 m
3
/h
850 m
3
/h
Operating range (temperature)
3 °C to 40 °C
Max. permissible pressure
3.0 MPa
Pressure suction side
0.7 MPa
Pressure outlet side
2.7 MPa
Nominal voltage
220 – 240 V / 50 Hz
Power consumption, max.
2.1 kW
Nominal current
9.8 A
Refrigerant
R-454C
Amount of refrigerant
900 g
GWP factor
146
CO
2
equivalent
0.13 t
Dimensions
(length x width x height)
500 x 565 x 960 mm
Minimum distance to walls and
other objects
A: top:
B: rear:
C: side:
D: front:
50 cm
50 cm
50 cm
50 cm
Weight
69 kg
Содержание TTK 900 MP
Страница 1: ...TRT BA TTK900MP TC2021 11 001 EN TTK 900 MP EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...
Страница 10: ...10 EN dehumidifier TTK 900 MP 3 4 5 6 7 8...
Страница 17: ...EN 17 dehumidifier TTK 900 MP Wiring diagram TTK 900 MP With operating hours counter...
Страница 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...