Trotec TTK 900 MP Скачать руководство пользователя страница 2

2

EN

dehumidifier TTK 900 MP

Table of contents

Notes regarding the instructions .......................................... 2

Safety ..................................................................................... 2

Information about the device................................................ 5

Transport and storage........................................................... 6

Assembly and start-up.......................................................... 7

Operation ............................................................................. 11

Available accessories.......................................................... 12

Errors and faults.................................................................. 12

Maintenance ........................................................................ 13

Technical annex................................................................... 16

Disposal ............................................................................... 22

Declaration of conformity ................................................... 22

Notes regarding the instructions

Symbols

Danger

This symbol indicates dangers to the life and health of
persons due to flammable refrigerants.

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information (e.g.
material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
instructions must be observed.

You can download the current version of the instructions and
the EU declaration of conformity via the following link:

TTK 900 MP

https://hub.trotec.com/?id=44937

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms or
areas and do not install it there.

Do not use the device in aggressive atmosphere.

Only put up the device in an upright, stable position on firm
ground.

Let the device dry out after a wet clean. Do not operate it
when wet.

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover the device during operation.

Do not sit on the device.

This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.

Содержание TTK 900 MP

Страница 1: ...TRT BA TTK900MP TC2021 11 001 EN TTK 900 MP EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Страница 2: ...nk TTK 900 MP https hub trotec com id 44937 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use War...

Страница 3: ...afety warnings for devices containing flammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is...

Страница 4: ...e Any use other than the intended use is regarded as a reasonably foreseeable misuse Personnel qualifications People who use this device must be aware of the dangers that occur when working with elect...

Страница 5: ...nect a defective device to the mains Information about the device Device description The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through...

Страница 6: ...the maximum number of components to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a transport handle and tw...

Страница 7: ...the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe the minimum dista...

Страница 8: ...sen the screw 14 2 Remove the screw 13 13 14 15 3 Turn the transport handle by 90 13 14 4 Insert the screw 13 in the rivet 15 5 Tighten the screws 14 15 Inserting the air filter Note Do not operate th...

Страница 9: ...in hose as follows Place a sufficiently dimensioned container at least 90 litres beside the device and insert the hose end Check the filling level of the container regularly Position the end of the co...

Страница 10: ...10 EN dehumidifier TTK 900 MP 3 4 5 6 7 8...

Страница 11: ...19 The device is switched on The compressor always starts with a delay of approx 7 s The fan starts approx 10 s after that Continuous operation mode In continuous operation mode the device dehumidifie...

Страница 12: ...lower value The device is running but there is no formation of condensate Check whether the condensation drain hose is positioned correctly When using the condensate pump Check the condensation tank...

Страница 13: ...crews X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Empty the condensate pump condensation tank and constructio...

Страница 14: ...safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Make sure that no moistu...

Страница 15: ...aused by ejected compressed air upon activation of the compressed air supply Hold the compressed air hose away from your body Pointing the compressed air hose at another person is prohibited Note If r...

Страница 16: ...ice to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter Technical annex Technical data Parameter Value Model TTK...

Страница 17: ...EN 17 dehumidifier TTK 900 MP Wiring diagram TTK 900 MP With operating hours counter...

Страница 18: ...tions of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY H1 Top panel 1 H8 Tubular handle screw 4 H2 Right panel 1 H9 Saddle spacer 4 H3 Left panel 1 H10...

Страница 19: ...of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY B1 Base plate 1 B8 Tubular foot 1 B2 Compressor 1 B9 Saddle foot 2 B3 Running capacitor 1 B10 Round in...

Страница 20: ...g the positions of the components mentioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY C1 Sealed electronic controller 1 C6 Defrost valve coil 2 C2 Body sheet metal 1 C7 Fan...

Страница 21: ...entioned in these instructions ITEM NO PART NUMBER QTY ITEM NO PART NUMBER QTY D1 Control s box 1 D7 Remote humidistat socket 1 D2 Control s cover 1 D8 Control s box internal wiring 1 D3 Electronic co...

Страница 22: ...se of the refrigerant appropriately and according to the national regulations Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part...

Страница 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Отзывы: