Trotec PV4-MID-PS Скачать руководство пользователя страница 6

6

EN

multiple socket outlet PV4-MID-PS

Technical data

Parameter

PV4-MID-PS

Input voltage

230 V , 50 Hz

Power consumption

max. 3.6 kVA

Preliminary fuse

max. 16 A or max. 2300 W

Socket

4 x safety socket CEE 7/3

Connection cable

H07RN-F 3G2.5, l = 2 m
safety plug CEE 7/7

Type of protection

IP44

Operating temperature

-20 °C – 45 °C

Storage temperature

-25 °C – 55 °C

Dimensions

450 x109 130 mm

Weight

2.85 kg

Rated diversity factor; RDF

0.25"

Parameter

Residual current device (RCD)

Rated current

25 A, type A, pulse current sensitive

Rated residual current

≤ 0.03 A (I∆n)

Rated voltage

230 V , 50 Hz

Parameter

MID-compliant energy meter

General information

Housing in accordance with

DIN 43880

Terminals according to

EN 60999

Nominal voltage

230 V ± 20 %

Max. power input

1,5 V – 1 W

Nominal frequency

50/60 Hz

Current

Max. current Imax

40 A

Reference current Iref (lb)

5 A

Transfer current Itr

500 mA

Min. current Imin

250 mA

Starting current Ist

20 mA

Accuracy

Active energy class B
according to

EN 50470-3 (MID)

Active energy class 1
according to

EN 62053-21 (NO MID)

Reactive energy class 2
according to

EN 62053-23

S0 output

Passive optoisolated

Max. values (according to
directive EN 602053-31)

27 V DC – 27 mA

Meter constant. The measuring
unit (lmp/kWh, lmp/kVAh, lmp/
kvarh) changes accordingly to
the corresponding
counters (kWh, kVAh, kvarh).

1000 imp/kWh

Pulse duration

100 ± 0.5 ms

Metrological test LED

Meter constant

5000 imp/kWh

Pulse duration

4 ± 0.1 ms

Connectable conductor

For measuring voltage and
current

1.5 ... 6 mm²

for S0 output

0.14 ... 2.5 mm²

Safety according to EN 50470-1

Degree of pollution

2

Protection class (EN 50470-1) II

Pulse voltage test

1.2/50µs 6 kV

AC voltage test
(EN 50470-3, 7.2)

4 kV

Flammability resistance
housing

UL 94 class VO

Ambient conditions

Mechanical environment class M1

Electromagnetic environment
class

E2

Operating temperature range

-25 °C – + 55 °C

Storage temperature range

-40 °C – + 75 °C

Relative humidity (without
condensation)

80 % max.

Sinusoidal vibration amplitude 50 Hz ± 0.075 mm

Protection type – front

IP 50

Protection type – terminals

IP 20

Содержание PV4-MID-PS

Страница 1: ...TRT BA PV4 MID PS TC2019 63 001 EN PV4 MID PS EN OPERATING MANUAL MULTIPLE SOCKET OUTLET...

Страница 2: ...mediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious...

Страница 3: ...bed in this manual is prohibited Non observance renders all claims for liability and guarantee null and void Intended use The device serves as mobile multiple socket outlet The multiple socket outlet...

Страница 4: ...e description The device serves for the mobile power supply on varying application devices It comes with the following device characteristics 4 safety sockets CEE 7 3 with one PlugSafe appliance each...

Страница 5: ...t for seal 10 Safety socket cover 11 PlugSafe appliance 12 Seal 13 Anchoring for seal 14 Open end of seal 15 Terminals for neutral conductors 16 Multifunction button 17 Metrological LED 18 Backlit LC...

Страница 6: ...20 mA Accuracy Active energy class B according to EN 50470 3 MID Active energy class 1 according to EN 62053 21 NO MID Reactive energy class 2 according to EN 62053 23 S0 output Passive optoisolated...

Страница 7: ...orage temperature is the same as the range given in the Technical data chapter Start up Warning of electrical voltage Work on the electrical components must only be carried out by a qualified electric...

Страница 8: ...unauthorised access by means of one or more seals 12 Securing the multiple socket outlet can be realised whether a plug has been inserted into the safety socket 5 or not One seal 12 per plug or safet...

Страница 9: ...nctions or settings are controlled via the multifunction button 16 The symbol indicates a standard value the indicates a bidirectional value All total counter values kWh kVAh kvarh can be assigned to...

Страница 10: ...nter records the total consumption If required the partial counter can be activated in addition to record a value during a certain period of time The partial counter can be started stopped and reset 1...

Страница 11: ...unction button 16 for 3 s During these 3 seconds 3 bars will be displayed next to the Stop sequence Once the Stop sequence is completely indicated the partial counter will be stopped The symbol will b...

Страница 12: ...enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe t...

Страница 13: ...is reached the inspection intervals may be extended to max once per year Checking the residual current device Info Generally the power supply of all consumers is interrupted for testing the residual...

Страница 14: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...